WEKO3
アイテム
Comparison of surgically induced astigmatism between one-handed and two-handed cataract surgery techniques
https://asahikawa-med.repo.nii.ac.jp/records/4877
https://asahikawa-med.repo.nii.ac.jp/records/4877220ad63a-76e3-4fcc-aea6-d57207860139
名前 / ファイル | ライセンス | アクション |
---|---|---|
![]() |
|
Item type | 学術雑誌論文 / Journal Article_02(1) | |||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
公開日 | 2014-05-08 | |||||||||||||||||
タイトル | ||||||||||||||||||
タイトル | Comparison of surgically induced astigmatism between one-handed and two-handed cataract surgery techniques | |||||||||||||||||
言語 | ||||||||||||||||||
言語 | eng | |||||||||||||||||
キーワード | ||||||||||||||||||
主題Scheme | Other | |||||||||||||||||
キーワード | cataract surgery | |||||||||||||||||
キーワード | ||||||||||||||||||
主題Scheme | Other | |||||||||||||||||
キーワード | corneal side port | |||||||||||||||||
キーワード | ||||||||||||||||||
主題Scheme | Other | |||||||||||||||||
キーワード | surgically induced astigmatism | |||||||||||||||||
資源タイプ | ||||||||||||||||||
資源タイプ | journal article | |||||||||||||||||
著者 |
河原, 温
× 河原, 温
× Kurosaka, Daijiro
× 吉田, 晃敏
|
|||||||||||||||||
著者 ローマ字 | ||||||||||||||||||
Kawahara, Atsushi | ||||||||||||||||||
著者 ローマ字 | ||||||||||||||||||
Kurosaka, Daijiro | ||||||||||||||||||
著者 ローマ字 | ||||||||||||||||||
Yoshida, Akitoshi | ||||||||||||||||||
書誌情報 |
Clinical Ophthalmology 巻 7, p. 1967-1972, 発行日 2013-10-01 |
|||||||||||||||||
ISSN | ||||||||||||||||||
収録物識別子タイプ | ISSN | |||||||||||||||||
収録物識別子 | 1177-5467 | |||||||||||||||||
DOI | ||||||||||||||||||
関連タイプ | isIdenticalTo | |||||||||||||||||
識別子タイプ | DOI | |||||||||||||||||
関連識別子 | 10.2147/OPTH.S52415 | |||||||||||||||||
識別番号 その他 | ||||||||||||||||||
内容記述タイプ | Other | |||||||||||||||||
内容記述 | PMID:24124349 | |||||||||||||||||
抄録 | ||||||||||||||||||
内容記述タイプ | Abstract | |||||||||||||||||
内容記述 | BACKGROUND: The purpose of this study was to compare surgically induced astigmatism (SIA) between one-handed and two-handed cataract surgery techniques. \nMETHODS: Eighty-eight eyes of 44 patients with no ocular disease other than cataract, who underwent cataract surgery by a single surgeon, were selected for this study. Cataract surgery was performed by coaxial phacoemulsification and intraocular lens implantation via a 2.4 mm transconjunctival single-plane sclerocorneal incision at the 12 o'clock position. In each patient, one eye was subjected to coaxial phacoemulsification using a one-handed technique while the fellow eye was subjected to coaxial phacoemulsification using a two-handed technique. For the two-handed technique, a corneal side port was created at the 2 o'clock position. The appropriate incision meridian was identified by a preoperative axis mark. SIA was calculated using the Alpins method. \nRESULTS: Mean SIA was 0.40 ± 0.28 diopters (D) in the one-handed technique group and 0.39 ± 0.25 D in the two-handed technique group. No statistically significant difference was found in the mean SIA score. The mean torque value was -0.05 ± 0.26 D in the one-handed technique group and 0.11 ± 0.37 D in the two-handed technique group. Mean torque was significantly lower (P<0.05) in the one-handed technique group than in the two-handed technique group. \nCONCLUSION: The results indicate that the corneal side port in two-handed cataract surgery has a rotating effect on the axis of astigmatism. |
|||||||||||||||||
注記 | ||||||||||||||||||
内容記述タイプ | Other | |||||||||||||||||
注記 | Publisher | |||||||||||||||||
資源タイプ | ||||||||||||||||||
内容記述タイプ | Other | |||||||||||||||||
資源タイプ | text | |||||||||||||||||
著者版フラグ | ||||||||||||||||||
出版タイプ | VoR | |||||||||||||||||
フォーマット | ||||||||||||||||||
内容記述タイプ | Other | |||||||||||||||||
内容記述 | application/pdf | |||||||||||||||||
ID(XooNIps) | ||||||||||||||||||
24124349 | ||||||||||||||||||
閲覧数(XooNIps) | ||||||||||||||||||
ダウンロード数(XooNIps) | ||||||||||||||||||
895 |