{"created":"2023-06-19T11:24:12.071053+00:00","id":4877,"links":{},"metadata":{"_buckets":{"deposit":"471d022b-04de-4600-8ce3-1e9438149ac1"},"_deposit":{"created_by":1,"id":"4877","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"4877"},"status":"published"},"_oai":{"id":"oai:asahikawa-med.repo.nii.ac.jp:00004877","sets":["7","7:24"]},"author_link":["15044","15046","15045"],"item_5_biblio_info_21":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2013-10-01","bibliographicIssueDateType":"Issued"},"bibliographicPageEnd":"1972","bibliographicPageStart":"1967","bibliographicVolumeNumber":"7","bibliographic_titles":[{"bibliographic_title":"Clinical Ophthalmology"}]}]},"item_5_description_28":{"attribute_name":"識別番号 その他","attribute_value_mlt":[{"subitem_description":"PMID:24124349","subitem_description_type":"Other"}]},"item_5_description_33":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"BACKGROUND: The purpose of this study was to compare surgically induced astigmatism (SIA) between one-handed and two-handed cataract surgery techniques.\n\\nMETHODS: Eighty-eight eyes of 44 patients with no ocular disease other than cataract, who underwent cataract surgery by a single surgeon, were selected for this study. Cataract surgery was performed by coaxial phacoemulsification and intraocular lens implantation via a 2.4 mm transconjunctival single-plane sclerocorneal incision at the 12 o'clock position. In each patient, one eye was subjected to coaxial phacoemulsification using a one-handed technique while the fellow eye was subjected to coaxial phacoemulsification using a two-handed technique. For the two-handed technique, a corneal side port was created at the 2 o'clock position. The appropriate incision meridian was identified by a preoperative axis mark. SIA was calculated using the Alpins method.\n\\nRESULTS: Mean SIA was 0.40 ± 0.28 diopters (D) in the one-handed technique group and 0.39 ± 0.25 D in the two-handed technique group. No statistically significant difference was found in the mean SIA score. The mean torque value was -0.05 ± 0.26 D in the one-handed technique group and 0.11 ± 0.37 D in the two-handed technique group. Mean torque was significantly lower (P<0.05) in the one-handed technique group than in the two-handed technique group.\n\\nCONCLUSION: The results indicate that the corneal side port in two-handed cataract surgery has a rotating effect on the axis of astigmatism.","subitem_description_type":"Abstract"}]},"item_5_description_36":{"attribute_name":"内容記述","attribute_value_mlt":[{"subitem_description":"Publisher","subitem_description_type":"Other"}]},"item_5_description_37":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"subitem_description":"text","subitem_description_type":"Other"}]},"item_5_description_41":{"attribute_name":"フォーマット","attribute_value_mlt":[{"subitem_description":"application/pdf","subitem_description_type":"Other"}]},"item_5_relation_24":{"attribute_name":"DOI","attribute_value_mlt":[{"subitem_relation_type":"isIdenticalTo","subitem_relation_type_id":{"subitem_relation_type_id_text":"10.2147/OPTH.S52415","subitem_relation_type_select":"DOI"}}]},"item_5_source_id_22":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"1177-5467","subitem_source_identifier_type":"ISSN"}]},"item_5_text_44":{"attribute_name":"ID(XooNIps)","attribute_value_mlt":[{"subitem_text_value":"24124349"}]},"item_5_text_54":{"attribute_name":"閲覧数(XooNIps)","attribute_value_mlt":[{"subitem_text_value":"864"}]},"item_5_text_55":{"attribute_name":"ダウンロード数(XooNIps)","attribute_value_mlt":[{"subitem_text_value":"895"}]},"item_5_text_7":{"attribute_name":"著者 ローマ字","attribute_value_mlt":[{"subitem_text_value":"Kawahara, Atsushi"},{"subitem_text_value":"Kurosaka, Daijiro"},{"subitem_text_value":"Yoshida, Akitoshi"}]},"item_5_version_type_38":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"河原, 温"},{"creatorName":"カワハラ, アツシ","creatorNameLang":"ja-Kana"}],"nameIdentifiers":[{"nameIdentifier":"15044","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Kurosaka, Daijiro"},{"creatorName":"クロサカ, ダイジロウ","creatorNameLang":"ja-Kana"}],"nameIdentifiers":[{"nameIdentifier":"15045","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"吉田, 晃敏"},{"creatorName":"ヨシダ, アキトシ","creatorNameLang":"ja-Kana"}],"nameIdentifiers":[{"nameIdentifier":"15046","nameIdentifierScheme":"WEKO"}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2021-07-06"}],"displaytype":"detail","filename":"5715.pdf","filesize":[{"value":"286.0 kB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"5715.pdf","url":"https://asahikawa-med.repo.nii.ac.jp/record/4877/files/5715.pdf"},"version_id":"5d6ebf5c-d120-4758-b964-f0f235e4f368"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"cataract surgery","subitem_subject_scheme":"Other"},{"subitem_subject":"corneal side port","subitem_subject_scheme":"Other"},{"subitem_subject":"surgically induced astigmatism","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"Comparison of surgically induced astigmatism between one-handed and two-handed cataract surgery techniques","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Comparison of surgically induced astigmatism between one-handed and two-handed cataract surgery techniques"}]},"item_type_id":"5","owner":"1","path":["6","7","24"],"pubdate":{"attribute_name":"公開日","attribute_value":"2014-05-08"},"publish_date":"2014-05-08","publish_status":"0","recid":"4877","relation_version_is_last":true,"title":["Comparison of surgically induced astigmatism between one-handed and two-handed cataract surgery techniques"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-06-19T12:34:14.343191+00:00"}