WEKO3
アイテム
Comparison of right ventricular function between three-dimensional transesophageal echocardiography and pulmonary artery catheter
https://asahikawa-med.repo.nii.ac.jp/records/2000276
https://asahikawa-med.repo.nii.ac.jp/records/20002761994f0fd-d790-4396-941b-c4e0df574f8d
| 名前 / ファイル | ライセンス | アクション |
|---|---|---|
|
|
|
| Item type | 学位論文 / Thesis or Dissertation_02(1) | |||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 公開日 | 2021-11-05 | |||||||||||
| タイトル | ||||||||||||
| タイトル | Comparison of right ventricular function between three-dimensional transesophageal echocardiography and pulmonary artery catheter | |||||||||||
| 言語 | en | |||||||||||
| 言語 | ||||||||||||
| 言語 | jpn | |||||||||||
| キーワード | ||||||||||||
| 言語 | en | |||||||||||
| 主題Scheme | Other | |||||||||||
| 主題 | pulmonary artery catheter | |||||||||||
| キーワード | ||||||||||||
| 言語 | en | |||||||||||
| 主題Scheme | Other | |||||||||||
| 主題 | right ventricular function | |||||||||||
| キーワード | ||||||||||||
| 言語 | en | |||||||||||
| 主題Scheme | Other | |||||||||||
| 主題 | right ventricular volume | |||||||||||
| キーワード | ||||||||||||
| 言語 | en | |||||||||||
| 主題Scheme | Other | |||||||||||
| 主題 | three-dimensional transesophageal echocardiography | |||||||||||
| 資源タイプ | ||||||||||||
| 資源タイプ識別子 | http://purl.org/coar/resource_type/c_db06 | |||||||||||
| 資源タイプ | doctoral thesis | |||||||||||
| アクセス権 | ||||||||||||
| アクセス権 | open access | |||||||||||
| アクセス権URI | http://purl.org/coar/access_right/c_abf2 | |||||||||||
| その他(別言語等)のタイトル | ||||||||||||
| その他のタイトル | 3次元経食道心エコーと肺動脈カテーテルによる右心機能測定の比較 | |||||||||||
| 言語 | ja | |||||||||||
| 著者 |
矢野, 喜一
× 矢野, 喜一
|
|||||||||||
| bibliographic_information |
en : Journal of cardiothoracic and vascular anesthesia 巻 35, 号 6, p. 1663-1669, 発行日 2021-06-01 |
|||||||||||
| ISSN | ||||||||||||
| 収録物識別子タイプ | PISSN | |||||||||||
| 収録物識別子 | 1053-0770 | |||||||||||
| DOI | ||||||||||||
| 関連タイプ | isIdenticalTo | |||||||||||
| 識別子タイプ | DOI | |||||||||||
| 関連識別子 | https://doi.org/10.1053/j.jvca.2020.11.012 | |||||||||||
| 識別番号 その他 | ||||||||||||
| 内容記述タイプ | Other | |||||||||||
| 内容記述 | PMID:33268041 | |||||||||||
| 言語 | en | |||||||||||
| dissertation_number | ||||||||||||
| 学位授与番号 | 甲第558号 | |||||||||||
| 学位授与年月日 | ||||||||||||
| 学位授与年月日 | 2021-03-25 | |||||||||||
| 学位名 | ||||||||||||
| 言語 | ja | |||||||||||
| 学位名 | 博士(医学) | |||||||||||
| item_10_degree_grantor_32 | ||||||||||||
| 言語 | ja | |||||||||||
| 学位授与機関名 | 旭川医科大学 | |||||||||||
| item_10_description_33 | ||||||||||||
| 内容記述タイプ | Abstract | |||||||||||
| 内容記述 | Objective: This study aimed to compare measurements of right ventricular function using three-dimensional transesophageal echocardiography (3D TEE), and pulmonary artery catheters (PACs) in patients undergoing cardiac surgery. The authors examined the practicality of using the 3D TEE. Design: Prospective observational. Setting: Cardiac operating room at a single university hospital. Participants: All adult patients undergoing elective cardiac surgery at a single tertiary care university hospital over two years. Interventions: None. Measurements and main results: Right ventricular end-diastolic volume (RVEDV), right ventricular end-systolic volume (RVESV), stroke volume (SV), and right ventricular ejection fraction (RVEF) were measured with both 3D TEE and PACs. Assessments were performed using correlation coefficients, paired t tests, and Bland-Altman plots. Thirty-one patients participated in this study. Each measurement showed good agreement. RVEDV and RVESV were slightly lower on 3D TEE than on PAC (205.9 mL v 220.2 mL, p = 0.0018; 143.0 mL v 155.5 mL, p = 0.0143, respectively), whereas no significant differences were observed for SV and RVEF (31.0% v 31.1%, p = 0.0569; 61.6 mL v 66.9 mL, p = 0.92, respectively). Linear regression analysis showed high correlation between 3D TEE and PAC for RVEDV (r = 0.87) and RVESV (r = 0.81), and moderate correlation for SV (r = 0.67) and RVEF (r = 0.67). In the Bland-Altman plot, most patients were within the 95% limits of the agreement throughout all measurements. Conclusion: A high correlation was found between measurements made with a PAC and with 3D TEE in the assessment of right ventricular function. Three-dimensional TEE would be a potential alternative to PAC for assessment of right ventricular function during intraoperative periods. |
|||||||||||
| 言語 | en | |||||||||||
| 出版タイプ | ||||||||||||
| 出版タイプ | NA | |||||||||||
| 出版タイプResource | http://purl.org/coar/version/c_be7fb7dd8ff6fe43 | |||||||||||