{"created":"2025-01-21T01:49:14.127036+00:00","id":2000276,"links":{},"metadata":{"_buckets":{"deposit":"47164c19-0192-4218-8076-02f7fdd09242"},"_deposit":{"created_by":3,"id":"2000276","owner":"3","owners":[3],"pid":{"revision_id":0,"type":"depid","value":"2000276"},"status":"published"},"_oai":{"id":"oai:asahikawa-med.repo.nii.ac.jp:02000276","sets":["7:27:45"]},"author_link":[],"item_10_alternative_title_3":{"attribute_name":"その他(別言語等)のタイトル","attribute_value_mlt":[{"subitem_alternative_title":"3次元経食道心エコーと肺動脈カテーテルによる右心機能測定の比較","subitem_alternative_title_language":"ja"}]},"item_10_biblio_info_21":{"attribute_name":"bibliographic_information","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2021-06-01","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"6","bibliographicPageEnd":"1669","bibliographicPageStart":"1663","bibliographicVolumeNumber":"35","bibliographic_titles":[{"bibliographic_title":"Journal of cardiothoracic and vascular anesthesia","bibliographic_titleLang":"en"}]}]},"item_10_date_granted_30":{"attribute_name":"学位授与年月日","attribute_value_mlt":[{"subitem_dategranted":"2021-03-25"}]},"item_10_degree_grantor_32":{"attribute_name":"item_10_degree_grantor_32","attribute_value_mlt":[{"subitem_degreegrantor":[{"subitem_degreegrantor_language":"ja","subitem_degreegrantor_name":"旭川医科大学"}],"subitem_degreegrantor_identifier":[{"subitem_degreegrantor_identifier_name":"10107","subitem_degreegrantor_identifier_scheme":"kakenhi"}]}]},"item_10_degree_name_31":{"attribute_name":"学位名","attribute_value_mlt":[{"subitem_degreename":"博士(医学)","subitem_degreename_language":"ja"}]},"item_10_description_28":{"attribute_name":"識別番号 その他","attribute_value_mlt":[{"subitem_description":"PMID:33268041","subitem_description_language":"en","subitem_description_type":"Other"}]},"item_10_description_33":{"attribute_name":"item_10_description_33","attribute_value_mlt":[{"subitem_description":"Objective: This study aimed to compare measurements of right ventricular function using three-dimensional transesophageal echocardiography (3D TEE), and pulmonary artery catheters (PACs) in patients undergoing cardiac surgery. The authors examined the practicality of using the 3D TEE.\n\nDesign: Prospective observational.\n\nSetting: Cardiac operating room at a single university hospital.\n\nParticipants: All adult patients undergoing elective cardiac surgery at a single tertiary care university hospital over two years.\n\nInterventions: None.\n\nMeasurements and main results: Right ventricular end-diastolic volume (RVEDV), right ventricular end-systolic volume (RVESV), stroke volume (SV), and right ventricular ejection fraction (RVEF) were measured with both 3D TEE and PACs. Assessments were performed using correlation coefficients, paired t tests, and Bland-Altman plots. Thirty-one patients participated in this study. Each measurement showed good agreement. RVEDV and RVESV were slightly lower on 3D TEE than on PAC (205.9 mL v 220.2 mL, p = 0.0018; 143.0 mL v 155.5 mL, p = 0.0143, respectively), whereas no significant differences were observed for SV and RVEF (31.0% v 31.1%, p = 0.0569; 61.6 mL v 66.9 mL, p = 0.92, respectively). Linear regression analysis showed high correlation between 3D TEE and PAC for RVEDV (r = 0.87) and RVESV (r = 0.81), and moderate correlation for SV (r = 0.67) and RVEF (r = 0.67). In the Bland-Altman plot, most patients were within the 95% limits of the agreement throughout all measurements.\n\nConclusion: A high correlation was found between measurements made with a PAC and with 3D TEE in the assessment of right ventricular function. Three-dimensional TEE would be a potential alternative to PAC for assessment of right ventricular function during intraoperative periods.","subitem_description_language":"en","subitem_description_type":"Abstract"}]},"item_10_dissertation_number_29":{"attribute_name":"dissertation_number","attribute_value_mlt":[{"subitem_dissertationnumber":"甲第558号"}]},"item_10_relation_24":{"attribute_name":"DOI","attribute_value_mlt":[{"subitem_relation_type":"isIdenticalTo","subitem_relation_type_id":{"subitem_relation_type_id_text":"https://doi.org/10.1053/j.jvca.2020.11.012","subitem_relation_type_select":"DOI"}}]},"item_10_source_id_22":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"1053-0770","subitem_source_identifier_type":"PISSN"}]},"item_10_version_type_38":{"attribute_name":"出版タイプ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_be7fb7dd8ff6fe43","subitem_version_type":"NA"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"open access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_abf2"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"矢野, 喜一","creatorNameLang":"ja","creatorNameType":"Personal"},{"creatorName":"ヤノ, キイチ","creatorNameLang":"ja-Kana","creatorNameType":"Personal"},{"creatorName":"Yano, Kiichi","creatorNameLang":"en","creatorNameType":"Personal"}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_access","date":[{"dateType":"Available","dateValue":"2025-01-21"}],"filename":"K558 Yano Kiichi_AB.pdf","filesize":[{"value":"407 KB"}],"format":"application/pdf","url":{"objectType":"summary","url":"https://asahikawa-med.repo.nii.ac.jp/record/2000276/files/K558 Yano Kiichi_AB.pdf"},"version_id":"22056633-522d-4035-9d36-214d8c763f5b"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"pulmonary artery catheter","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"right ventricular function","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"right ventricular volume","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"three-dimensional transesophageal echocardiography","subitem_subject_language":"en","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"item_resource_type","attribute_value_mlt":[{"resourcetype":"doctoral thesis","resourceuri":"http://purl.org/coar/resource_type/c_db06"}]},"item_title":"Comparison of right ventricular function between three-dimensional transesophageal echocardiography and pulmonary artery catheter","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Comparison of right ventricular function between three-dimensional transesophageal echocardiography and pulmonary artery catheter","subitem_title_language":"en"}]},"item_type_id":"10","owner":"3","path":["45"],"pubdate":{"attribute_name":"PubDate","attribute_value":"2021-11-05"},"publish_date":"2021-11-05","publish_status":"0","recid":"2000276","relation_version_is_last":true,"title":["Comparison of right ventricular function between three-dimensional transesophageal echocardiography and pulmonary artery catheter"],"weko_creator_id":"3","weko_shared_id":-1},"updated":"2025-01-21T02:10:38.521545+00:00"}