ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. Public
  1. Public
  2. 国外雑誌論文

Improved accuracy in estimation of left ventricular function parameters from QGS software with Tc-99m tetrofosmin gated-SPECT: a multivariate analysis.

https://asahikawa-med.repo.nii.ac.jp/records/709
https://asahikawa-med.repo.nii.ac.jp/records/709
00152b8d-7018-4db4-9fa4-b1272452f476
名前 / ファイル ライセンス アクション
889.pdf 889.pdf (676.6 kB)
Item type 学術雑誌論文 / Journal Article_02(1)
公開日 2008-03-28
タイトル
タイトル Improved accuracy in estimation of left ventricular function parameters from QGS software with Tc-99m tetrofosmin gated-SPECT: a multivariate analysis.
言語 en
言語
言語 eng
資源タイプ
資源タイプ journal article
著者 沖崎, 貴琢

× 沖崎, 貴琢

沖崎, 貴琢

ja-Kana オキザキ, アツタカ

Search repository
Shuke, N

× Shuke, N

Shuke, N

Search repository
Ishikawa, Y

× Ishikawa, Y

Ishikawa, Y

Search repository
Yamamoto, W

× Yamamoto, W

Yamamoto, W

Search repository
Kikuchi, K

× Kikuchi, K

Kikuchi, K

Search repository
Aburano, T

× Aburano, T

Aburano, T

Search repository
著者 ローマ字
Okizaki, Atsutaka
書誌情報 Annals of Nuclear Medicine

巻 17, 号 7, p. 575-582, 発行日 2003-10-01
ISSN
収録物識別子タイプ ISSN
収録物識別子 0914-7187
リンクURL
内容記述タイプ Other
内容記述 http://www.jsnm.org/files/paper/anm/ams177/ANM17-7-09.pdf | http://www.jsnm.org/files/paper/anm/ams177/ANM17-7-09.pdf
抄録
内容記述タイプ Abstract
内容記述 The purpose of this study was to verify whether the accuracy of left ventricular parameters related to left ventricular function from gated-SPECT improved or not, using multivariate analysis. METHODS: Ninety-six patients with cardiovascular diseases were studied. Gated-SPECT with the QGS software and left ventriculography (LVG) were performed to obtain left ventricular ejection fraction (LVEF), end-diastolic volume (EDV) and end-systolic volume (ESV). Then, multivariate analyses were performed to determine empirical formulas for predicting these parameters. The calculated values of left ventricular parameters were compared with those obtained directly from the QGS software and LVG. RESULTS: Multivariate analyses were able to improve accuracy in estimation of LVEF, EDV and ESV. Statistically significant improvement was seen in LVEF (from r = 0.6965 to r = 0.8093, p < 0.05). Although not statistically significant, improvements in correlation coefficients were seen in EDV (from r = 0.7199 to r = 0.7595, p = 0.2750) and ESV (from r = 0.5694 to r = 0.5871, p = 0.4281). CONCLUSION: The empirical equations with multivariate analysis improved the accuracy in estimating LVEF from gated-SPECT with the QGS software.
注記
内容記述タイプ Other
注記 The original publication is available at www.springerlink.com
\nauthor
資源タイプ
内容記述タイプ Other
資源タイプ text
著者版フラグ
出版タイプ AM
フォーマット
内容記述タイプ Other
内容記述 application/pdf
ID(XooNIps)
14651357
閲覧数(XooNIps)
ダウンロード数(XooNIps)
1561
戻る
0
views
See details
Views

Versions

Ver.1 2023-06-19 13:55:33.839279
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3