ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. Public
  1. Public
  2. 国外雑誌論文

SUV navigator enables rapid [18F]-FDG PET/CT image interpretation compared with 2D ROI and 3D VOI evaluations

https://asahikawa-med.repo.nii.ac.jp/records/5939
https://asahikawa-med.repo.nii.ac.jp/records/5939
65e3e42f-13b3-4043-b472-20daad6941fa
名前 / ファイル ライセンス アクション
7057.pdf 7057.pdf (6.2 MB)
Item type 学術雑誌論文 / Journal Article_02(1)
公開日 2018-09-25
タイトル
タイトル SUV navigator enables rapid [18F]-FDG PET/CT image interpretation compared with 2D ROI and 3D VOI evaluations
言語
言語 eng
キーワード
主題Scheme Other
キーワード FDG PET
キーワード
主題Scheme Other
キーワード Image interpretation
キーワード
主題Scheme Other
キーワード SUV measurement
キーワード
主題Scheme Other
キーワード Standardized uptake value
資源タイプ
資源タイプ journal article
著者 沖崎, 貴琢

× 沖崎, 貴琢

沖崎, 貴琢

ja-Kana オキザキ, アツタカ

Search repository
中山, 理寛

× 中山, 理寛

中山, 理寛

ja-Kana ナカヤマ, ミチヒロ

Search repository
石戸谷, 俊太

× 石戸谷, 俊太

石戸谷, 俊太

ja-Kana イシトヤ, シュンタ

Search repository
中島, 香織

× 中島, 香織

中島, 香織

ja-Kana ナカジマ, カオリ

Search repository
山品, 将祥

× 山品, 将祥

山品, 将祥

ja-Kana ヤマシナ, マサアキ

Search repository
油野, 民雄

× 油野, 民雄

油野, 民雄

ja-Kana アブラノ, タミオ

Search repository
髙橋, 康二

× 髙橋, 康二

髙橋, 康二

ja-Kana タカハシ, コウジ

Search repository
著者 ローマ字
Okizaki, Atsutaka
著者 ローマ字
Nakayama, Michihiro
著者 ローマ字
Ishitoya, Shunta
著者 ローマ字
Nakajima, Kaori
著者 ローマ字
Yamashina, Masaaki
著者 ローマ字
Aburano, Tamio
著者 ローマ字
Takahashi, Koji
書誌情報 Japanese Journal of Radiology

巻 35, 号 7, p. 398-403, 発行日 2017-07-01
ISSN
収録物識別子タイプ ISSN
収録物識別子 1867-1071
DOI
関連タイプ isVersionOf
識別子タイプ DOI
関連識別子 10.1007/s11604-017-0645-8
識別番号 その他
内容記述タイプ Other
内容記述 PMID:28497349
抄録
内容記述タイプ Abstract
内容記述 PURPOSE:
\nPositron emission tomography (PET) and the maximum standardized uptake value (SUVmax) is a useful technique for assessing malignant tumors. Measurements of SUVmax in multiple lesions per patient frequently require many time-consuming procedures. To address this issue, we designed a novel interface named SUV Navigator (SUVnavi), and the purpose of this study was to investigate its utility.
MATERIALS AND METHODS:
\nWe measured SUVmax in 661 lesions from 100 patients with malignant tumors. Diagnoses and SUVmax measurements were made with SUVnavi, 2D, and 3D measurements. SUV measurement accuracy in each method were also evaluated.
RESULTS:
\nThe average reduction in time with SUVnavi versus 2D was 53.8% and 3D was 37.5%; time required with SUVnavi was significantly shorter than with 2D and 3D (P < 0.001 and P < 0.001, respectively). The time reduction and lesion number had a positive correlation (P < 0.001 and P < 0.001, respectively). SUVmax agreed with precise SUVmax in all lesions measured with SUVnavi and 3D but in only 466 of 661 lesions (70.5%) measured with 2D.
CONCLUSION:
\nSUVnavi may be useful for rapid [18F]-fluorodeoxyglucose positron emission tomography/computed tomography ([18F]-FDG PET/CT) image interpretation without reducing the accuracy of SUVmax measurement.
資源タイプ
内容記述タイプ Other
資源タイプ text
著者版フラグ
出版タイプ AM
フォーマット
内容記述タイプ Other
内容記述 application/pdf
ID(XooNIps)
28497349
閲覧数(XooNIps)
ダウンロード数(XooNIps)
319
戻る
0
views
See details
Views

Versions

Ver.1 2023-06-19 12:07:51.444405
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3