WEKO3
アイテム
Pilot study of endoscopic retrograde 3-dimensional - computed tomography enteroclysis for the assessment of Crohn's disease
https://asahikawa-med.repo.nii.ac.jp/records/5897
https://asahikawa-med.repo.nii.ac.jp/records/5897a070cec3-1830-411a-9c46-4f3005fc22bb
名前 / ファイル | ライセンス | アクション |
---|---|---|
![]() |
|
Item type | 学術雑誌論文 / Journal Article_02(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2018-06-04 | |||||
タイトル | ||||||
タイトル | Pilot study of endoscopic retrograde 3-dimensional - computed tomography enteroclysis for the assessment of Crohn's disease | |||||
言語 | ||||||
言語 | eng | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | 3-Dimension | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | Computed tomography | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | Crohn’s disease | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | ER 3D-CTE | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | endoscopic retrograde 3-dimensional | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | ERIG | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | endoscopic retrograde ileography | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | Ileography | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
著者 |
田邊, 裕貴
× 田邊, 裕貴× 伊藤, 貴博× 稲場, 勇平× 安藤, 勝祥× 野村, 好紀× 上野, 伸展× 嘉島, 伸× 盛一, 健太郎× 藤谷, 幹浩× 奥村, 利勝 |
|||||
著者 ローマ字 | ||||||
値 | Tanabe, Hiroki | |||||
著者 ローマ字 | ||||||
値 | Ito, Takahiro | |||||
著者 ローマ字 | ||||||
値 | Inaba, Yuhei | |||||
著者 ローマ字 | ||||||
値 | Ando, Katsuyoshi | |||||
著者 ローマ字 | ||||||
値 | Nomura, Yoshiki | |||||
著者 ローマ字 | ||||||
値 | Ueno, Nobuhiro | |||||
著者 ローマ字 | ||||||
値 | Kashima, Shin | |||||
著者 ローマ字 | ||||||
値 | Moriichi, Kentaro | |||||
著者 ローマ字 | ||||||
値 | Fujiya, Mikihiro | |||||
著者 ローマ字 | ||||||
値 | Okumura, Toshikatsu | |||||
書誌情報 |
European Journal of Radiology Open 巻 4, p. 58-62, 発行日 2017-05-01 |
|||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 2352-0477 | |||||
DOI | ||||||
関連タイプ | isIdenticalTo | |||||
識別子タイプ | DOI | |||||
関連識別子 | 10.1016/j.ejro.2017.04.003 | |||||
識別番号 その他 | ||||||
内容記述タイプ | Other | |||||
内容記述 | PMID:28508024 | |||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | PURPOSE: \nEndoscopic retrograde ileography (ERIG) is developed in our institute and applied clinically for the diagnosis and assessment of the Crohn's disease activity. We have further improved the technique using 3-dimensional - computed tomography enteroclysis (3D-CTE) and conducted a retrospective study to determine the feasibility and the diagnostic value of endoscopic retrograde 3D-CTE (ER 3D-CTE) in Crohn's disease patients in a state of remission. METHODS: \nThirteen Crohn's patients were included in this pilot study. CTE was performed after the infusion of air or CO2 through the balloon tube following conventional colonoscopy. The primary endpoint of this study was to assess the safety of this method. Secondarily, the specific findings of Crohn's disease and length of the visualized small intestine were assessed. RESULTS: \nThe procedures were completed without any adverse events. Gas passed through the small intestine and enterographic images were obtained in 10 out of 13 cases, but, in the remaining patients, insertion of the balloon tubes into the terminal ileum failed. Various features specific to Crohn's disease were visualized using ER 3D-CTE. A cobble stone appearance or hammock-like malformation was specific and effective for diagnosing Crohn's disease and the features of anastomosis after the surgical operations were also well described. Therefore, this technique may be useful after surgery. CONCLUSION: \nIn this study, ER 3D-CTE was performed safely in Crohn's disease patients and may be used for the diagnosis and follow-up of this disease. |
|||||
注記 | ||||||
内容記述タイプ | Other | |||||
内容記述 | This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/BY-NC-ND/4.0/ | |||||
資源タイプ | ||||||
内容記述タイプ | Other | |||||
内容記述 | text | |||||
著者版フラグ | ||||||
出版タイプ | VoR | |||||
出版タイプResource | http://purl.org/coar/version/c_970fb48d4fbd8a85 | |||||
フォーマット | ||||||
内容記述タイプ | Other | |||||
内容記述 | application/pdf | |||||
ID(XooNIps) | ||||||
値 | 28508024 | |||||
閲覧数(XooNIps) | ||||||
値 | 424 | |||||
ダウンロード数(XooNIps) | ||||||
値 | 415 |