ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. Public
  1. Public
  2. 国外雑誌論文

Early Deformation of Hip Articular Cartilage Under A High Load Before and After Labral Excision

https://asahikawa-med.repo.nii.ac.jp/records/5893
https://asahikawa-med.repo.nii.ac.jp/records/5893
3a889729-7c87-4563-a853-df9b1b8c2eab
名前 / ファイル ライセンス アクション
7000.pdf 7000.pdf (763.4 kB)
Item type 学術雑誌論文 / Journal Article_02(1)
公開日 2018-05-31
タイトル
タイトル Early Deformation of Hip Articular Cartilage Under A High Load Before and After Labral Excision
言語
言語 eng
キーワード
主題Scheme Other
キーワード Hip Joint
キーワード
主題Scheme Other
キーワード Labrum
キーワード
主題Scheme Other
キーワード Cartilage
キーワード
主題Scheme Other
キーワード MRI
資源タイプ
資源タイプ journal article
著者 伊藤, 浩

× 伊藤, 浩

伊藤, 浩

ja-Kana イトウ, ヒロシ

Search repository
中村, 聡喜

× 中村, 聡喜

中村, 聡喜

ja-Kana ナカムラ, トシキ

Search repository
佐藤, 達也

× 佐藤, 達也

佐藤, 達也

ja-Kana サトウ, タツヤ

Search repository
西田, 恭博

× 西田, 恭博

西田, 恭博

ja-Kana ニシダ, ヤスヒロ

Search repository
谷野, 弘昌

× 谷野, 弘昌

谷野, 弘昌

ja-Kana タニノ, ヒロマサ

Search repository
比嘉, 昌

× 比嘉, 昌

比嘉, 昌

ja-Kana ヒガ, マサル

Search repository
著者 ローマ字
Ito, Hiroshi
著者 ローマ字
Nakamura, Toshiki
著者 ローマ字
Sato, Tatsuya
著者 ローマ字
Nishida, Yasuhiro
著者 ローマ字
Tanino, Hiromasa
著者 ローマ字
Higa, Masaru
書誌情報 Journal of Arthritis

巻 6, 号 2, p. 1000237, 発行日 2017-04-01
ISSN
収録物識別子タイプ ISSN
収録物識別子 2167-7921
DOI
関連タイプ isIdenticalTo
識別子タイプ DOI
関連識別子 10.4172/2167-7921.1000237
抄録
内容記述タイプ Abstract
内容記述 Background: It has been reported that the function of the labrum is to ensure that an increased surface area encountered the femoral head and spares the cartilage from excessive strain. The purpose of this study was to determine whether early deformation of the hip articular cartilage occurs under high-load conditions in the presence/absence of the labrum.
\nMethods: The hip joints of 4 beagle dogs were retrieved. A continuous static load of 80 Kg was applied for 2.5 hours. Magnetic resonance imaging (MRI) was performed immediately after the loading and at 30, 60, 90, 120, and 150 minutes after the loading. The load was then removed, and the specimens were stored for 14 h to allow the cartilage to recover. The labrum was then carefully removed, and the experiment was performed again.
\nResults: The maximum percentage change in cartilage thickness was 35.3 ± 17.4% when the labrum was intact and 55.7± 7.5% after the labrum had been excised (p=0.060). Labral excision resulted in a reduction in cartilage thickness. Cartilage thickness was significantly decreased in the normal and labral excision models immediately after loading (p=0.003 and p=0.022, respectively).
\nConclusion: The labrum plays a role in dispersing loads equally across the joint cartilage and reduces the load placed on the maximum weight-bearing region of cartilage. Early articular cartilage deformation occurred under high-load conditions both before and after the excision of the labrum.
注記
内容記述タイプ Other
注記 This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
資源タイプ
内容記述タイプ Other
資源タイプ text
著者版フラグ
出版タイプ VoR
フォーマット
内容記述タイプ Other
内容記述 application/pdf
ID(XooNIps)
2018053101
閲覧数(XooNIps)
ダウンロード数(XooNIps)
446
戻る
0
views
See details
Views

Versions

Ver.1 2023-06-19 12:08:53.773482
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3