WEKO3
アイテム
Evaluation of cerebral circulation during retrograde perfusion by laser speckle flowgraphy.
https://asahikawa-med.repo.nii.ac.jp/records/5703
https://asahikawa-med.repo.nii.ac.jp/records/5703b54a517b-7160-45ea-ad61-2a377bc80167
名前 / ファイル | ライセンス | アクション |
---|---|---|
![]() |
|
Item type | 学術雑誌論文 / Journal Article_02(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2017-08-18 | |||||
タイトル | ||||||
タイトル | Evaluation of cerebral circulation during retrograde perfusion by laser speckle flowgraphy. | |||||
言語 | ||||||
言語 | eng | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | Cerebral circulation | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | Laser speckle flowgraphy | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | Retrograde cerebral perfusion | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
著者 |
木村, 文昭
× 木村, 文昭× 神田, 浩嗣× 遠山, 裕樹× 国沢, 卓之× 長岡, 泰司× 吉田, 晃敏× Kitahara, Hiroto× 紙谷, 寛之 |
|||||
著者 ローマ字 | ||||||
値 | Kimura, Fumiaki | |||||
著者 ローマ字 | ||||||
値 | Kanda, Hirotsugu | |||||
著者 ローマ字 | ||||||
値 | Toyama, Yuki | |||||
著者 ローマ字 | ||||||
値 | Kunisawa, Takayuki | |||||
著者 ローマ字 | ||||||
値 | Nagaoka, Taiji | |||||
著者 ローマ字 | ||||||
値 | Yoshida, Akitoshi | |||||
著者 ローマ字 | ||||||
著者 ローマ字 | ||||||
値 | Kamiya, Hiroyuki | |||||
書誌情報 |
General Thoracic and Cardiovascular Surgery p. 1-5, 発行日 2016-11-01 |
|||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 1863-6705 | |||||
DOI | ||||||
関連タイプ | isIdenticalTo | |||||
識別子タイプ | DOI | |||||
関連識別子 | 10.1007/s11748-016-0727-z | |||||
識別番号 その他 | ||||||
内容記述タイプ | Other | |||||
内容記述 | PMID:27900535 | |||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | Laser speckle flowgraphy (LSFG) is an ophthalmologic equipment that qualitatively detects the blood flow of the optic nerve head, which is known to be related with cerebral microcirculation. LSFG can also measure the mean blur rate, which quantitatively calculates the blood flow. We aimed to assess the utility of LSFG in the evaluation of cerebral perfusion during aortic surgery under hypothermic circulatory arrest with retrograde and antegrade cerebral perfusion. Two patients underwent total arch replacement for aneurysm. The blood flow of the optic nerve head was monitored with LSFG and the mean blur rate value was measured during the surgery. The LSFG could detect the blood flow quantitatively in the optic nerve head during both retrograde and antegrade cerebral perfusion; and the value was correlated with rSO2 value. | |||||
注記 | ||||||
内容記述タイプ | Other | |||||
内容記述 | This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/) | |||||
資源タイプ | ||||||
内容記述タイプ | Other | |||||
内容記述 | text | |||||
著者版フラグ | ||||||
出版タイプ | VoR | |||||
出版タイプResource | http://purl.org/coar/version/c_970fb48d4fbd8a85 | |||||
フォーマット | ||||||
内容記述タイプ | Other | |||||
内容記述 | application/pdf | |||||
ID(XooNIps) | ||||||
値 | 27900535 | |||||
閲覧数(XooNIps) | ||||||
値 | 527 | |||||
ダウンロード数(XooNIps) | ||||||
値 | 732 |