Functional characteristics of left ventricular synchronization via right ventricular outflow-tract pacing detected by two-dimensional strain echocardiography

https://asahikawa-med.repo.nii.ac.jp/records/5661
https://asahikawa-med.repo.nii.ac.jp/records/5661
483a5a07-952a-475f-8da8-372ab6c41f40
名前 / ファイル ライセンス アクション
6711.pdf 6711.pdf (1.7 MB)
Item type 学位論文 / Thesis or Dissertation_02(1)
公開日 2017-04-27
タイトル
タイトル Functional characteristics of left ventricular synchronization via right ventricular outflow-tract pacing detected by two-dimensional strain echocardiography
言語 en
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_db06
資源タイプ doctoral thesis
アクセス権
アクセス権 open access
アクセス権URI http://purl.org/coar/access_right/c_abf2
著者 平山, 康高

× 平山, 康高

ja 平山, 康高

ja-Kana ヒラヤマ, ヤスタカ

Search repository
著者 ローマ字
Hirayama, Yasutaka
書誌情報 Journal of arrhythmia

巻 33, 号 1, p. 28-34, 発行日 2017-02-01
ISSN
収録物識別子タイプ ISSN
収録物識別子 1880-4276
DOI
識別子タイプ DOI
関連識別子 10.1016/j.joa.2016.04.009.
識別番号 その他
内容記述タイプ Other
内容記述 PMID:28217226
学位授与番号
学位授与番号 乙467
学位授与年月日
学位授与年月日 2017-03-24
学位名
学位名 博士(医学)
学位授与機関
学位授与機関名 旭川医科大学
内容記述
内容記述タイプ Other
内容記述 BACKGROUND:
\nRecently, due to the detrimental effects on the ventricular function associated with right ventricular apical (RVA) pacing, right ventricular septal (RVS) pacing has become the preferred pacing method. However, the term RVS pacing refers to both right ventricular outflow-tract (RVOT) and mid-septal (RVMS) pacing, leading to a misinterpretation of the results of clinical studies. The purpose of this study, therefore, was to elucidate the functional differences of RVA, RVOT, and RVMS pacing in patients with atrioventricular block.
METHODS:
\nWe compared the QRS duration, global longitudinal strain (GLS), and left ventricular (LV) synchronization parameters at the three pacing sites in 47 patients. The peak systolic strain (PSS) time delay between the earliest and latest segments among the 18 LV segments and standard deviation (SD) of the time to the PSS were also calculated for the 18 LV segments at each pacing site using two-dimensional (2D) strain echocardiography.
RESULTS:
\nRVMS pacing was associated with a significantly shorter QRS duration compared with RVA and RVOT pacing (154.4±21.4 vs 186.5±19.9 and 171.1±21.5 ms, P<0.001). In contrast, RVOT pacing revealed a greater GLS (-14.69±4.92 vs -13.12±4.76 and -13.51±4.81%, P<0.001), shorter PSS time delay between the earliest and latest segments (236.0±87.9 vs 271.3±102.9 and 281.9±126.6%, P=0.007), and shorter SD of the time to the PSS (70.8±23.8 vs 82.7±30.8 and 81.5±33.7 ms, P=0.002) compared with RVA and RVMS pacing.
CONCLUSIONS:
\nThese results suggest that the functional characteristics of RVOT pacing may be a more optimal pacing site than RVMS, regardless of the pacing QRS duration, in patients with atrioventricular conduction disorders.
資源タイプ
内容記述タイプ Other
内容記述 application/pdf
著者版フラグ
出版タイプ VoR
出版タイプResource http://purl.org/coar/version/c_970fb48d4fbd8a85
フォーマット
内容記述タイプ Other
内容記述 application/pdf
戻る
0
views
See details
Views

Versions

Ver.1 2023-06-19 12:15:58.188753
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

平山, 康高, n.d., Functional characteristics of left ventricular synchronization via right ventricular outflow-tract pacing detected by two-dimensional strain echocardiography: 28–34 p.

Loading...

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3