WEKO3
-
RootNode
アイテム
Patency of small laser iridotomy evaluated using anterior-segment optical coherence tomography.
https://asahikawa-med.repo.nii.ac.jp/records/5258
https://asahikawa-med.repo.nii.ac.jp/records/5258e3687fe9-b2f7-4fd0-a910-e6066466c606
名前 / ファイル | ライセンス | アクション |
---|---|---|
![]() |
|
Item type | 学術雑誌論文 / Journal Article_02(1) | |||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
公開日 | 2015-09-01 | |||||||||||||||||||||
タイトル | ||||||||||||||||||||||
タイトル | Patency of small laser iridotomy evaluated using anterior-segment optical coherence tomography. | |||||||||||||||||||||
言語 | ||||||||||||||||||||||
言語 | eng | |||||||||||||||||||||
キーワード | ||||||||||||||||||||||
主題Scheme | Other | |||||||||||||||||||||
キーワード | acute angle-closure glaucoma | |||||||||||||||||||||
キーワード | ||||||||||||||||||||||
主題Scheme | Other | |||||||||||||||||||||
キーワード | anterior-segment optical coherence tomography | |||||||||||||||||||||
キーワード | ||||||||||||||||||||||
主題Scheme | Other | |||||||||||||||||||||
キーワード | laser iridotomy | |||||||||||||||||||||
資源タイプ | ||||||||||||||||||||||
資源タイプ | journal article | |||||||||||||||||||||
著者 |
中林, 征吾
× 中林, 征吾
× 川井, 基史
× 山口, 亨
× 吉田, 晃敏
|
|||||||||||||||||||||
著者 ローマ字 | ||||||||||||||||||||||
Nakabayashi, Seigo | ||||||||||||||||||||||
著者 ローマ字 | ||||||||||||||||||||||
Kawai, Motofumi | ||||||||||||||||||||||
著者 ローマ字 | ||||||||||||||||||||||
Yamaguchi, Toru | ||||||||||||||||||||||
著者 ローマ字 | ||||||||||||||||||||||
Yoshida, Akitoshi | ||||||||||||||||||||||
書誌情報 |
Clinical Ophthalmology 巻 8, p. 595-597, 発行日 2014-03-01 |
|||||||||||||||||||||
ISSN | ||||||||||||||||||||||
収録物識別子タイプ | ISSN | |||||||||||||||||||||
収録物識別子 | 1177-5467 | |||||||||||||||||||||
DOI | ||||||||||||||||||||||
関連タイプ | isIdenticalTo | |||||||||||||||||||||
識別子タイプ | DOI | |||||||||||||||||||||
関連識別子 | 10.2147/OPTH.S60405 | |||||||||||||||||||||
識別番号 その他 | ||||||||||||||||||||||
内容記述タイプ | Other | |||||||||||||||||||||
内容記述 | PMID:24711692 | |||||||||||||||||||||
抄録 | ||||||||||||||||||||||
内容記述タイプ | Abstract | |||||||||||||||||||||
内容記述 | We report the case of a patient with recurrent acute angle-closure glaucoma who had undergone a previous laser iridotomy. Because the initial iridotomy was small, patency could not be determined by slit-lamp examination. Therefore, anterior-segment optical coherence tomography was used to evaluate the patency. Cross-sectional images showed the presence of a membrane with an anterior bowing configuration at the base of the iridotomy, suggesting that recurrent pupillary block was the causative mechanism. A repeat laser iridotomy was performed, with a resultant decrease in the intraocular pressure and widening of the anterior chamber angle. Anterior-segment optical coherence tomography may be helpful to confirm the status of a laser iridotomy, especially when the iridotomy is small. | |||||||||||||||||||||
注記 | ||||||||||||||||||||||
内容記述タイプ | Other | |||||||||||||||||||||
注記 | オープンアクセス CC-BY-NC |
|||||||||||||||||||||
資源タイプ | ||||||||||||||||||||||
内容記述タイプ | Other | |||||||||||||||||||||
資源タイプ | text | |||||||||||||||||||||
著者版フラグ | ||||||||||||||||||||||
出版タイプ | VoR | |||||||||||||||||||||
フォーマット | ||||||||||||||||||||||
内容記述タイプ | Other | |||||||||||||||||||||
内容記述 | application/pdf | |||||||||||||||||||||
ID(XooNIps) | ||||||||||||||||||||||
24711692 | ||||||||||||||||||||||
閲覧数(XooNIps) | ||||||||||||||||||||||
ダウンロード数(XooNIps) | ||||||||||||||||||||||
398 |
Share
Cite as
中林, 征吾, 川井, 基史, 山口, 亨, 吉田, 晃敏, n.d., Patency of small laser iridotomy evaluated using anterior-segment optical coherence tomography.: 595–597 p.
Loading...