Item type |
学術雑誌論文 / Journal Article_02(1) |
公開日 |
2014-10-08 |
タイトル |
|
|
タイトル |
Non-transferrin-bound iron assay system utilizing a conventional automated analyzer. |
言語 |
|
|
言語 |
eng |
キーワード |
|
|
主題Scheme |
Other |
|
キーワード |
Iron overload |
キーワード |
|
|
主題Scheme |
Other |
|
キーワード |
Automated analyzer |
キーワード |
|
|
主題Scheme |
Other |
|
キーワード |
Iron toxicity |
キーワード |
|
|
主題Scheme |
Other |
|
キーワード |
Nitroso-PSAP |
キーワード |
|
|
主題Scheme |
Other |
|
キーワード |
Non-transferrin-bound iron |
キーワード |
|
|
主題Scheme |
Other |
|
キーワード |
Quantification |
資源タイプ |
|
|
資源タイプ |
journal article |
著者 |
伊藤, 巧
生田, 克哉
■, ■
渋佐, 琴恵
■, ■
■, ■
Lynda, Addo
土岐, 康通
畑山, 真弓
稲村, 純季
進藤, 基博
■, ■
■, ■
藤谷, 幹浩
鳥本, 悦宏
高後, 裕
|
著者 ローマ字 |
|
|
|
Ito, Satoshi |
著者 ローマ字 |
|
|
|
Ikuta, Katsuya |
著者 ローマ字 |
|
|
|
Kato, Daisuke |
著者 ローマ字 |
|
|
|
Shibusa, Kotoe |
著者 ローマ字 |
|
|
|
Niizeki, Noriyasu |
著者 ローマ字 |
|
|
|
Tanaka, Hiroki |
著者 ローマ字 |
|
|
|
DUMMY, NAME |
著者 ローマ字 |
|
|
|
Toki, Yasumichi |
著者 ローマ字 |
|
|
|
Hatayama, Mayumi |
著者 ローマ字 |
|
|
|
Inamura, Junki |
著者 ローマ字 |
|
|
|
Shindo, Motohiro |
著者 ローマ字 |
|
|
|
Sasaki, Katsunori |
著者 ローマ字 |
|
|
|
Iizuka, Naomi |
著者 ローマ字 |
|
|
|
Mikihiro, Fujiya |
著者 ローマ字 |
|
|
|
Torimoto, Yoshihiro |
著者 ローマ字 |
|
|
|
Kohgo, Yutaka |
書誌情報 |
Clin Chim Acta
号 437,
p. 129-135,
発行日 2014-09-01
|
ISSN |
|
|
収録物識別子タイプ |
ISSN |
|
収録物識別子 |
1873-3492 |
DOI |
|
|
関連タイプ |
isVersionOf |
|
|
識別子タイプ |
DOI |
|
|
関連識別子 |
10.1016/j.cca.2014.07.013 |
識別番号 その他 |
|
|
内容記述 |
PMID:25072389 |
抄録 |
|
|
内容記述タイプ |
Abstract |
|
内容記述 |
Iron is an essential metal in the body, but its excessive accumulation causes damage in various organs through free radical production. Iron homeostasis is therefore tightly regulated. However, when iron balance collapses, such as in prolonged transfusion, transferrin (Tf) is fully saturated and non-Tf-bound iron (NTBI) appears in the serum. Monitoring serum NTBI levels is therefore crucial in assessment of the clinical status of patients with iron overload, since NTBI is associated with cellular and organ damage. Several methods for NTBI determination have been reported, but these are extremely complicated and very few laboratories can quantify NTBI at present. In this study, we established a novel assay system utilizing automated analyzers that are widely used in clinical laboratories for diagnostic testing. In this assay, NTBI is chelated by nitrilotriacetic acid (NTA), after which the iron is reduced and transferred to nitroso-PSAP, a chromogen. The assay shows excellent linearity, reproducibility, and compatibility with HPLC, one of the most reliable conventional methods for NTBI quantification. Our novel method for NTBI measurement is high-throughput and may be a useful and powerful tool in study of the physiological and clinical importance of NTBI. |
注記 |
|
|
内容記述タイプ |
Other |
|
注記 |
author |
資源タイプ |
|
|
内容記述タイプ |
Other |
|
資源タイプ |
text |
著者版フラグ |
|
|
出版タイプ |
AM |
フォーマット |
|
|
内容記述タイプ |
Other |
|
内容記述 |
application/pdf |
ID(XooNIps) |
|
|
|
25072389 |
閲覧数(XooNIps) |
|
ダウンロード数(XooNIps) |
|
|
|
1377 |