ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. Public
  1. Public
  2. 国外雑誌論文

Improved quantification for non-transferrin-bound iron measurement using high-performance liquid chromatography by reducing iron contamination

https://asahikawa-med.repo.nii.ac.jp/records/4006
https://asahikawa-med.repo.nii.ac.jp/records/4006
0e913136-c762-4586-8213-79f106187fa5
名前 / ファイル ライセンス アクション
4465.pdf 4465.pdf (604.4 kB)
Item type 学術雑誌論文 / Journal Article_02(1)
公開日 2012-05-17
タイトル
タイトル Improved quantification for non-transferrin-bound iron measurement using high-performance liquid chromatography by reducing iron contamination
言語 en
言語
言語 eng
資源タイプ
資源タイプ journal article
著者 佐々木, 勝則

× 佐々木, 勝則

ja 佐々木, 勝則

ja-Kana ササキ, カツノリ

Search repository
Ikuta, Katsuya

× Ikuta, Katsuya

en Ikuta, Katsuya

Search repository
Tanaka, Hiroki

× Tanaka, Hiroki

en Tanaka, Hiroki

Search repository
Ohtake, Takaaki

× Ohtake, Takaaki

en Ohtake, Takaaki

Search repository
Torimoto, Yoshihiro

× Torimoto, Yoshihiro

en Torimoto, Yoshihiro

Search repository
Fujiya, Mikihiro

× Fujiya, Mikihiro

en Fujiya, Mikihiro

Search repository
Kohgo, Yutaka

× Kohgo, Yutaka

en Kohgo, Yutaka

Search repository
書誌情報 Molecular Medicine Reports

巻 4, 号 5, p. 913-918, 発行日 2011-09-01
ISSN
収録物識別子タイプ PISSN
収録物識別子 1791-2997
DOI
関連タイプ isIdenticalTo
識別子タイプ DOI
関連識別子 10.3892/mmr.2011.518
抄録
内容記述タイプ Abstract
内容記述 Non-transferrin-bound iron (NTBI) refers to all forms of iron in the plasma that bind to ligands other than transferrin, and is considered to be a marker of iron toxicity. A variety of analytical approaches for measuring NTBI have been reported; however, a clinically relevant level of sensitivity has yet to be achieved. In addition, insufficient values of NTBI in some patients and healthy subjects have led to the assumption that there may be contamination of reagents with background iron. The present study re-evaluated the analytical procedures of the assay with regard to the potential points of iron contamination in each step. NTA and tris carbonatocobaltate (III) solutions were prepared with removal of iron contamination, and then quantification of NTBI was performed. As a result, the sensitivity of the high-performance liquid chromatography (HPLC)-based NTBI method was improved by the successful reduction of background iron contamination. Application of our modified method proved that NTBI was detected even in healthy volunteers, although the concentrations were extremely low; the average NTBI levels were 0.206±0.091 μM (males, n=20) and 0.212±0.095 μM (females, n=16). Thus, our modification of the NTBI assay may be clinically meaningful, and may contribute to the understanding of the clinical significance of relatively low, but elevated concentrations of NTBI in diseases other than typical iron overload.
言語 en
注記
内容記述タイプ Other
注記 Copyright © 2012 Spandidos Publications Ltd. Publisher
資源タイプ
内容記述タイプ Other
資源タイプ text
著者版フラグ
出版タイプ VoR
フォーマット
内容記述タイプ Other
内容記述 application/pdf
ID(XooNIps)
21720715
閲覧数(XooNIps)
ダウンロード数(XooNIps)
1158
戻る
0
views
See details
Views