The stability of total talar prosthesis - How stable to dislocation? Cadaveric study

https://asahikawa-med.repo.nii.ac.jp/records/2000310
https://asahikawa-med.repo.nii.ac.jp/records/2000310
b3dc74e1-8dc1-4d69-8ff4-bdb2bd417d56
名前 / ファイル ライセンス アクション
O495 O495 Sato Go_TD.pdf (631 KB)
Item type 学位論文 / Thesis or Dissertation_02(1)
公開日 2022-10-07
タイトル
タイトル The stability of total talar prosthesis - How stable to dislocation? Cadaveric study
言語 en
言語
言語 eng
キーワード
言語 en
主題Scheme Other
主題 ankle stability
キーワード
言語 en
主題Scheme Other
主題 talar comminuted fracture
キーワード
言語 en
主題Scheme Other
主題 talar necrosis
キーワード
言語 en
主題Scheme Other
主題 total talar prosthesis
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_db06
資源タイプ doctoral thesis
アクセス権
アクセス権 open access
アクセス権URI http://purl.org/coar/access_right/c_abf2
その他(別言語等)のタイトル
その他のタイトル 人工距骨の安定性-脱臼への耐性は如何ほどか? カダバ研究
言語 ja
著者 佐藤, 剛

× 佐藤, 剛

ja 佐藤, 剛

ja-Kana サトウ, ゴウ

en Sato, Go

Search repository
bibliographic_information en : Journal of orthopaedic research : official publication of the Orthopaedic Research Society

巻 40, 号 9, p. 2189-2195, 発行日 2022-09-01
ISSN
収録物識別子タイプ PISSN
収録物識別子 0736-0266
DOI
関連タイプ isVersionOf
識別子タイプ DOI
関連識別子 https://doi.org/10.1002/jor.25237
識別番号 その他
内容記述タイプ Other
内容記述 PMID:34897786
言語 en
dissertation_number
学位授与番号 乙第495号
学位授与年月日
学位授与年月日 2022-09-30
学位名
言語 ja
学位名 博士(医学)
item_10_degree_grantor_32
言語 ja
学位授与機関名 旭川医科大学
item_10_description_33
内容記述タイプ Abstract
内容記述 The aim of this study was to characterize ankle stability of total talar prosthesis (TTP) and to determine the effect of implant sizes on stability as well as the resistance to TTP dislocation. Twelve below-knee cadaveric specimens were divided into two groups. Group 1 received a size matched implant and Group 2 received downsized implant by 5%. The stability assessment under fluoroscopy was performed for each cadaver in its native state. Following TTP insertion process, each then underwent evaluation of the TTP ankle stability. The stability of pre- and post-TTP was compared. (1) Anterior drawer distance. (2) Talar tilt angle under varus and valgus stress. (3) Subtalar tilt angle under varus stress was measured. Finally, the dislocation test was performed using the aforementioned testing conditions, then the stress force was slowly increased from 0 to 350 N, during which time it was observed on fluoroscopy all the time. Compared to pre TTP ankles, varus and anterior drawer stress showed significant instability (p < 0.001-0.031). Only anterior drawer stress in smaller sized implants showed significant instability when compared to identical sized implants (p = 0.008). No dislocation was seen under varus, valgus, and subtalar stress. However, anterior dislocation was observed in all cases of smaller size implant group (p = 0.045). TTP implant was stable under valgus and subtalar stress. However, clinicians should pay attention to anterior instability. Notably, downsized implants should be considered carefully to minimize the chance of anterior dislocation.
言語 en
出版タイプ
出版タイプ AM
出版タイプResource http://purl.org/coar/version/c_ab4af688f83e57aa
戻る
0
views
See details
Views

Versions

Ver.1 2025-01-28 02:40:34.165689
Show All versions

Share

Mendeley Twitter Facebook Print Addthis