Item type |
学術雑誌論文 / Journal Article_02(1) |
公開日 |
2008-06-17 |
タイトル |
|
|
タイトル |
Comparative Study of Simple Semiquantitative Dust Mite Allergen Tests(簡易な半定量的ダニアレルゲン検査の比較研究) |
|
言語 |
en |
言語 |
|
|
言語 |
eng |
キーワード |
|
|
主題Scheme |
Other |
|
キーワード |
house dust |
キーワード |
|
|
主題Scheme |
Other |
|
キーワード |
mite allergen |
キーワード |
|
|
主題Scheme |
Other |
|
キーワード |
sick building syndrome |
キーワード |
|
|
主題Scheme |
Other |
|
キーワード |
allergy |
資源タイプ |
|
|
資源タイプ |
journal article |
著者 |
西條, 泰明
中木, 良彦
杉岡, 良彦
伊藤, 俊弘
遠藤, 整
黒田, 光
吉田, 貴彦
|
著者 ローマ字 |
|
|
|
Saijo, Yasuaki |
著者 ローマ字 |
|
|
|
en |
|
|
Nakagi, Yoshihiko |
著者 ローマ字 |
|
|
|
en |
|
|
Sugioka, Yoshihiko |
著者 ローマ字 |
|
|
|
en |
|
|
Ito, Toshihiro |
著者 ローマ字 |
|
|
|
en |
|
|
Endo, Hitoshi |
著者 ローマ字 |
|
|
|
en |
|
|
Kuroda, Hikaru |
著者 ローマ字 |
|
|
|
en |
|
|
Yoshida, Takahiko |
著者 ローマ字 |
|
|
|
en |
書誌情報 |
Environmental Health and Preventive Medicine
巻 12,
号 5,
p. 187-192,
発行日 2007-09-01
|
ISSN |
|
|
収録物識別子タイプ |
PISSN |
|
収録物識別子 |
1342-078X |
抄録 |
|
|
内容記述タイプ |
Abstract |
|
内容記述 |
Objective: Two simple, commercially available and semiquantitative dust mite allergen tests, namely, the Acarex test® and Mitey Checker®, were compared using 2 and 10 μg of Der 1 allergen per gram of dust, as evaluated by enzyme-linked immunosorbent assay (ELISA), to clarify which method is better suited for practical use. Methods: Mite allergen exposure levels of 106 floor, bed and sofa surfaces were evaluated by the Acarex test®, Mitey Checker®, and ELISA. A template of 100 cm × 100 cm was placed on the same surfaces to identify the examined areas. A dust collection filter was attached to a vacuum cleaner, and the area in the template (1 m2) was vacuumed. Then, to evaluate the other two tests, samples from the two other areas in the template (1 m2) that neighbored each other and did not overlap were vacuumed. Results: To predict Der 1 levels of 2 μg/g dust or higher, the sensitivity and specificity of the Acarex test® were 100% and 13.3%, and those of Mitey Checker® were 91.8% and 71.1%, respectively. To predict Der 1 levels of 10 μg/g dust or higher, the sensitivity and specificity of the Acarex test® were 50.0% and 96.2%, and those of Mitey Checker® were 85.7% and 79.5%, respectively. Compared with Der 1 <2.0, 2.0-9.9,>10.0 (μg/g dust), the percent agreement and kappa of the Acarex test® were 47.2% and 0.234, and those of Mitey Checker® were 70.0% and 0.505, respectively. Conclusion: To evaluate mite allergen exposure level for practical use in Japanese living environments, Mitey Checker® is better than the Acarex test® because of its higher sensitivity and specificity. |
|
言語 |
en |
注記 |
|
|
内容記述タイプ |
Other |
|
注記 |
雑誌掲載版 |
資源タイプ |
|
|
内容記述タイプ |
Other |
|
資源タイプ |
text |
著者版フラグ |
|
|
出版タイプ |
VoR |
フォーマット |
|
|
内容記述タイプ |
Other |
|
内容記述 |
application/pdf |
ID(XooNIps) |
|
|
|
2008127624 |
閲覧数(XooNIps) |
|
ダウンロード数(XooNIps) |
|
|
|
1053 |