{"created":"2023-06-19T11:20:46.432639+00:00","id":853,"links":{},"metadata":{"_buckets":{"deposit":"12f4a5cc-9495-462c-89a1-f11225d174b0"},"_deposit":{"created_by":3,"id":"853","owners":[3],"pid":{"revision_id":0,"type":"depid","value":"853"},"status":"published"},"_oai":{"id":"oai:asahikawa-med.repo.nii.ac.jp:00000853","sets":["7","7:23"]},"author_link":["2548","2549","2550","2551","2552","2553"],"item_5_biblio_info_21":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2007-11-01","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"11","bibliographicPageEnd":"1712","bibliographicPageStart":"1708","bibliographicVolumeNumber":"31","bibliographic_titles":[{"bibliographic_title":"臨床麻酔"}]}]},"item_5_description_33":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"エアウェイスコープとエアトラックでの気管挿管をマネキン人形を用いて比較検討した。展開時の喉頭蓋位置の処理が異なるものの、両者ともPercentage of glottic opening(POGO)スコア90%程度の良好な視野を得て、全例で初回挿管に成功した。所要時間は9±4vs15±6秒と有意にエアウェイスコープで短く、内蔵モニターで気道解剖を観察しながら喉頭にアプローチでき、ターゲットマークがチューブ進行の目安になるためと考えられた。しかし、時間の差に臨床的意義は少なく、おのおのの特徴を理解して使えば双方とも有用な気道確保道具になり得ることが示唆された。","subitem_description_language":"ja","subitem_description_type":"Abstract"}]},"item_5_description_36":{"attribute_name":"注記","attribute_value_mlt":[{"subitem_description":"出版社版","subitem_description_type":"Other"}]},"item_5_description_37":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"subitem_description":"text","subitem_description_type":"Other"}]},"item_5_description_41":{"attribute_name":"フォーマット","attribute_value_mlt":[{"subitem_description":"application/pdf","subitem_description_type":"Other"}]},"item_5_source_id_22":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"0387-3668","subitem_source_identifier_type":"PISSN"}]},"item_5_text_44":{"attribute_name":"ID(XooNIps)","attribute_value_mlt":[{"subitem_text_value":"2008087500"}]},"item_5_text_54":{"attribute_name":"閲覧数(XooNIps)","attribute_value_mlt":[{"subitem_text_value":"1713"}]},"item_5_text_55":{"attribute_name":"ダウンロード数(XooNIps)","attribute_value_mlt":[{"subitem_text_value":"2851"}]},"item_5_text_7":{"attribute_name":"著者 ローマ字","attribute_value_mlt":[{"subitem_text_value":"Suzuki, Akihiro"},{"subitem_text_language":"en","subitem_text_value":"Kikuchi, Chika"},{"subitem_text_language":"en","subitem_text_value":"Katsumi, Norifumi"},{"subitem_text_language":"en","subitem_text_value":"Goto, Yuya"},{"subitem_text_language":"en","subitem_text_value":"Takahata, Osamu"},{"subitem_text_language":"en","subitem_text_value":"Iwasaki, Hiroshi"},{"subitem_text_language":"en"}]},"item_5_version_type_38":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"鈴木, 昭広","creatorNameLang":"ja"},{"creatorName":"スズキ, アキヒロ","creatorNameLang":"ja-Kana"}],"nameIdentifiers":[{"nameIdentifier":"2548","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"菊地, 千歌","creatorNameLang":"ja"},{"creatorName":"キクチ, チカ","creatorNameLang":"ja-Kana"}],"nameIdentifiers":[{"nameIdentifier":"2549","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"勝見, 紀文","creatorNameLang":"ja"},{"creatorName":"カツミ, ノリフミ","creatorNameLang":"ja-Kana"}],"nameIdentifiers":[{"nameIdentifier":"2550","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"後藤, 祐也","creatorNameLang":"ja"},{"creatorName":"ゴトウ, ユウヤ","creatorNameLang":"ja-Kana"}],"nameIdentifiers":[{"nameIdentifier":"2551","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"高畑, 治","creatorNameLang":"ja"},{"creatorName":"タカハタ, オサム","creatorNameLang":"ja-Kana"}],"nameIdentifiers":[{"nameIdentifier":"2552","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"岩崎, 寛","creatorNameLang":"ja"},{"creatorName":"イワサキ, ヒロシ","creatorNameLang":"ja-Kana"}],"nameIdentifiers":[{"nameIdentifier":"2553","nameIdentifierScheme":"WEKO"}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2021-07-06"}],"displaytype":"detail","filename":"1046.pdf","filesize":[{"value":"1.6 MB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"1046.pdf","url":"https://asahikawa-med.repo.nii.ac.jp/record/853/files/1046.pdf"},"version_id":"fdf737bc-4842-464b-9a8c-fcd582786ca5"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"エアウェイスコープ","subitem_subject_language":"ja","subitem_subject_scheme":"Other"},{"subitem_subject":"エアトラック","subitem_subject_language":"ja","subitem_subject_scheme":"Other"},{"subitem_subject":"挿管困難","subitem_subject_language":"ja","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"マネキンモデルにおける新しい気道確保道具エアウェイスコープとエアトラックの使用比較","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"マネキンモデルにおける新しい気道確保道具エアウェイスコープとエアトラックの使用比較","subitem_title_language":"ja"}]},"item_type_id":"5","owner":"3","path":["6","7","23"],"pubdate":{"attribute_name":"PubDate","attribute_value":"2008-06-10"},"publish_date":"2008-06-10","publish_status":"0","recid":"853","relation_version_is_last":true,"title":["マネキンモデルにおける新しい気道確保道具エアウェイスコープとエアトラックの使用比較"],"weko_creator_id":"3","weko_shared_id":-1},"updated":"2024-07-16T09:38:18.932557+00:00"}