{"created":"2023-06-19T11:25:11.281371+00:00","id":6013,"links":{},"metadata":{"_buckets":{"deposit":"09485c4d-bc57-4998-86fd-f3954bb514c2"},"_deposit":{"created_by":1,"id":"6013","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"6013"},"status":"published"},"_oai":{"id":"oai:asahikawa-med.repo.nii.ac.jp:00006013","sets":["7","7:23"]},"author_link":["18987","18984","18986","18988","18985"],"item_5_biblio_info_21":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2018-06-01","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"3","bibliographicPageEnd":"267","bibliographicPageStart":"260","bibliographicVolumeNumber":"43","bibliographic_titles":[{"bibliographic_title":"日本臨床検査自動化学会会誌"}]}]},"item_5_description_33":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"生化学分析モジュール<c702>と免疫自動分析モジュール<e602>が統合されたハイブリッド型自動分析装置cobas8000<c702>|<e602>とその専用試薬の性能評価を行った。CKMBで遊離型ビリルビンの影響を認めた以外は良好な結果を得た。本装置はcobas8000<c702>のサンプルプローブを介した。特に免疫測定時のキャリーオーバーが懸念されるためHBs抗原高値検体を用い検討を実施した。キャリーオーバーは確認されなかった。cobas8000<c702>|<e602>は、生化学項目と免疫項目を同一検体よりサンプリング可能で業務の効率化、報告時間の短縮に加え、検査終了後検体での免疫項目の追加検査への適応が可能である。","subitem_description_type":"Abstract"}]},"item_5_description_37":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"subitem_description":"text","subitem_description_type":"Other"}]},"item_5_description_41":{"attribute_name":"フォーマット","attribute_value_mlt":[{"subitem_description":"application/pdf","subitem_description_type":"Other"}]},"item_5_relation_27":{"attribute_name":"医中誌ID","attribute_value_mlt":[{"subitem_relation_type":"isIdenticalTo","subitem_relation_type_id":{"subitem_relation_type_id_text":"2018256117","subitem_relation_type_select":"ICHUSHI"}}]},"item_5_source_id_22":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"0286-1607","subitem_source_identifier_type":"ISSN"}]},"item_5_text_44":{"attribute_name":"ID(XooNIps)","attribute_value_mlt":[{"subitem_text_value":"2018256117"}]},"item_5_text_54":{"attribute_name":"閲覧数(XooNIps)","attribute_value_mlt":[{"subitem_text_value":"267"}]},"item_5_text_55":{"attribute_name":"ダウンロード数(XooNIps)","attribute_value_mlt":[{"subitem_text_value":"202"}]},"item_5_text_7":{"attribute_name":"著者 ローマ字","attribute_value_mlt":[{"subitem_text_value":"Takahashi, Junya"},{"subitem_text_value":"Niizeki, Noriyasu"},{"subitem_text_value":"Kurose, Hitomi"},{"subitem_text_value":"Tomoda, Yutaka"},{"subitem_text_value":"Fujii, Satoshi"}]},"item_5_version_type_38":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"高橋, 順也"},{"creatorName":"タカハシ, ジュンヤ","creatorNameLang":"ja-Kana"}],"nameIdentifiers":[{"nameIdentifier":"18984","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"新関, 紀康"},{"creatorName":"ニイゼキ, ノリヤス","creatorNameLang":"ja-Kana"}],"nameIdentifiers":[{"nameIdentifier":"18985","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"黒瀬, 瞳"},{"creatorName":"クロセ, ヒトミ","creatorNameLang":"ja-Kana"}],"nameIdentifiers":[{"nameIdentifier":"18986","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"友田, 豊"},{"creatorName":"トモダ, ユタカ","creatorNameLang":"ja-Kana"}],"nameIdentifiers":[{"nameIdentifier":"18987","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"藤井, 聡"},{"creatorName":"フジイ, サトシ","creatorNameLang":"ja-Kana"}],"nameIdentifiers":[{"nameIdentifier":"18988","nameIdentifierScheme":"WEKO"}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2021-07-06"}],"displaytype":"detail","filename":"7147.pdf","filesize":[{"value":"3.4 MB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"7147.pdf","url":"https://asahikawa-med.repo.nii.ac.jp/record/6013/files/7147.pdf"},"version_id":"67b261cd-2f35-4a0d-ba7a-6d5bdc3ec450"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"cobas8000<c702>","subitem_subject_scheme":"Other"},{"subitem_subject":"<e602>","subitem_subject_scheme":"Other"},{"subitem_subject":"ハイブリッド型自動分析装置","subitem_subject_scheme":"Other"},{"subitem_subject":"キャリーオーバー","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"免疫生化学ハイブリッド型自動分析装置cobas8000<c702>|<e602>の基礎的検討","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"免疫生化学ハイブリッド型自動分析装置cobas8000<c702>|<e602>の基礎的検討"}]},"item_type_id":"5","owner":"1","path":["6","7","23"],"pubdate":{"attribute_name":"公開日","attribute_value":"2018-12-07"},"publish_date":"2018-12-07","publish_status":"0","recid":"6013","relation_version_is_last":true,"title":["免疫生化学ハイブリッド型自動分析装置cobas8000<c702>|<e602>の基礎的検討"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-06-19T12:04:58.647620+00:00"}