{"created":"2023-06-19T11:24:25.156356+00:00","id":5127,"links":{},"metadata":{"_buckets":{"deposit":"45cdd8c4-5468-443e-b098-196ee1a0ffaa"},"_deposit":{"created_by":1,"id":"5127","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"5127"},"status":"published"},"_oai":{"id":"oai:asahikawa-med.repo.nii.ac.jp:00005127","sets":["7","7:24"]},"author_link":["16063","16061","16062"],"item_5_biblio_info_21":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2014-01-01","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"1","bibliographicPageEnd":"43","bibliographicPageStart":"36","bibliographicVolumeNumber":"38","bibliographic_titles":[{"bibliographic_title":"Journal of Computer Assisted Tomography"}]}]},"item_5_description_28":{"attribute_name":"識別番号 その他","attribute_value_mlt":[{"subitem_description":"PMID:24424555","subitem_description_type":"Other"}]},"item_5_description_33":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"OBJECTIVES:\n\\nThe purpose of our study was to determine the prognostic value of normal stress cardiovascular magnetic resonance imaging (CMR) by a systematic literature review and meta-analysis.\nMETHODS:\n\\nA comprehensive literature search of published studies through November 2011 in MEDLINE database and Cochrane Library, regarding prognostic value of stress CMR in patients with known or suspected coronary artery disease, was performed.\nRESULTS:\n\\nUltimately, we identified 11 studies. The summary relative risk ratio for major adverse cardiac events was 0.50 (95% confidence interval [CI], 0.44-0.58) for normal cine CMR and 0.09 (95% CI, 0.02-0.35) for normal perfusion CMR. The summary relative risk ratio for hard cardiac events was 0.36 (95% CI, 0.16-0.8) for normal cine CMR and 0.22 (95% CI, 0.07-0.66) for normal perfusion CMR.\nCONCLUSIONS:\n\\nNormal stress CMR for patients known or suspected of having coronary artery disease has good prognostic value in predicting cardiac events.","subitem_description_type":"Abstract"}]},"item_5_description_36":{"attribute_name":"内容記述","attribute_value_mlt":[{"subitem_description":"著者最終版","subitem_description_type":"Other"}]},"item_5_description_37":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"subitem_description":"text","subitem_description_type":"Other"}]},"item_5_description_41":{"attribute_name":"フォーマット","attribute_value_mlt":[{"subitem_description":"application/pdf","subitem_description_type":"Other"}]},"item_5_relation_24":{"attribute_name":"DOI","attribute_value_mlt":[{"subitem_relation_type":"isVersionOf","subitem_relation_type_id":{"subitem_relation_type_id_text":"10.1097/RCT.0b013e3182a474a0.","subitem_relation_type_select":"DOI"}}]},"item_5_source_id_22":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"0363-8715","subitem_source_identifier_type":"ISSN"}]},"item_5_text_44":{"attribute_name":"ID(XooNIps)","attribute_value_mlt":[{"subitem_text_value":"24424555"}]},"item_5_text_54":{"attribute_name":"閲覧数(XooNIps)","attribute_value_mlt":[{"subitem_text_value":"725"}]},"item_5_text_55":{"attribute_name":"ダウンロード数(XooNIps)","attribute_value_mlt":[{"subitem_text_value":"535"}]},"item_5_text_7":{"attribute_name":"著者 ローマ字","attribute_value_mlt":[{"subitem_text_value":"Iwata, Kunihiro"},{"subitem_text_value":"Nakagawa, Sadahiro"},{"subitem_text_value":"Ogasawara, Katsuhiko"}]},"item_5_version_type_38":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_ab4af688f83e57aa","subitem_version_type":"AM"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"岩田, 邦弘"},{"creatorName":"イワタ, クニヒロ","creatorNameLang":"ja-Kana"}],"nameIdentifiers":[{"nameIdentifier":"16061","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"中川, 貞裕"},{"creatorName":"ナカガワ, サダヒロ","creatorNameLang":"ja-Kana"}],"nameIdentifiers":[{"nameIdentifier":"16062","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"小笠原, 克彦"},{"creatorName":"オガサワラ, カツヒコ","creatorNameLang":"ja-Kana"}],"nameIdentifiers":[{"nameIdentifier":"16063","nameIdentifierScheme":"WEKO"}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2021-07-06"}],"displaytype":"detail","filename":"6005.pdf","filesize":[{"value":"443.2 kB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"6005.pdf","url":"https://asahikawa-med.repo.nii.ac.jp/record/5127/files/6005.pdf"},"version_id":"a8e95c58-d962-439b-b647-8e160f44ac79"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"magnetic resonance imaging","subitem_subject_scheme":"Other"},{"subitem_subject":"meta-analysis","subitem_subject_scheme":"Other"},{"subitem_subject":"cardiac imaging techniques","subitem_subject_scheme":"Other"},{"subitem_subject":"prognosis","subitem_subject_scheme":"Other"},{"subitem_subject":"systematic review","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"The prognostic value of normal stress cardiovascular magnetic resonance imaging.","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"The prognostic value of normal stress cardiovascular magnetic resonance imaging."}]},"item_type_id":"5","owner":"1","path":["6","7","24"],"pubdate":{"attribute_name":"公開日","attribute_value":"2015-02-19"},"publish_date":"2015-02-19","publish_status":"0","recid":"5127","relation_version_is_last":true,"title":["The prognostic value of normal stress cardiovascular magnetic resonance imaging."],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-06-19T12:28:54.317515+00:00"}