{"created":"2023-06-19T11:24:00.877097+00:00","id":4654,"links":{},"metadata":{"_buckets":{"deposit":"44edf672-7e13-496a-8445-6fc05e3972c4"},"_deposit":{"created_by":3,"id":"4654","owners":[3],"pid":{"revision_id":0,"type":"depid","value":"4654"},"status":"published"},"_oai":{"id":"oai:asahikawa-med.repo.nii.ac.jp:00004654","sets":["7","7:23"]},"author_link":["14410","14411","14412","14413","14414"],"item_5_biblio_info_21":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2000-07-01","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"7","bibliographicPageEnd":"864","bibliographicPageStart":"862","bibliographicVolumeNumber":"94","bibliographic_titles":[{"bibliographic_title":"眼科臨床医報"}]}]},"item_5_description_33":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"集団検診受診者222名412眼(0歳から84歳(平均58.6歳))に対してニコン社製の手持ち式オートレフラクトケラトメーター「レチノマックスKプラス」と据置式オートレフラクトケラトメーターによって測定した屈折度と角膜曲率半径を比較検討した.レチノマックスKプラスは,強度近視においてやや低近視側に測定される傾向にあるが,据置式とほぼ同等の値が得られ,又,角膜曲率半径もほぼ同等の値が得られた.集団検診の視力検査,屈折異常に対するスクリーニングに有用な検査機器であると思われた","subitem_description_language":"ja","subitem_description_type":"Abstract"}]},"item_5_description_36":{"attribute_name":"注記","attribute_value_mlt":[{"subitem_description":"雑誌掲載版","subitem_description_type":"Other"}]},"item_5_description_37":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"subitem_description":"text","subitem_description_type":"Other"}]},"item_5_description_41":{"attribute_name":"フォーマット","attribute_value_mlt":[{"subitem_description":"application/pdf","subitem_description_type":"Other"}]},"item_5_source_id_22":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"0386-9601","subitem_source_identifier_type":"PISSN"}]},"item_5_text_44":{"attribute_name":"ID(XooNIps)","attribute_value_mlt":[{"subitem_text_value":"2001000178"}]},"item_5_text_54":{"attribute_name":"閲覧数(XooNIps)","attribute_value_mlt":[{"subitem_text_value":"756"}]},"item_5_text_55":{"attribute_name":"ダウンロード数(XooNIps)","attribute_value_mlt":[{"subitem_text_value":"1228"}]},"item_5_text_7":{"attribute_name":"著者 ローマ字","attribute_value_mlt":[{"subitem_text_value":"Konno, Suguru"},{"subitem_text_language":"en","subitem_text_value":"Nagaoka, Taiji"},{"subitem_text_language":"en","subitem_text_value":"Hanada, Kazuomi"},{"subitem_text_language":"en","subitem_text_value":"Yoshida, Akitoshi"},{"subitem_text_language":"en"}]},"item_5_version_type_38":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"佐藤, 栄一","creatorNameLang":"ja"},{"creatorName":"サトウ, エイイチ","creatorNameLang":"ja-Kana"}],"nameIdentifiers":[{"nameIdentifier":"14410","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"今野, 優","creatorNameLang":"ja"},{"creatorName":"コンノ, スグル","creatorNameLang":"ja-Kana"}],"nameIdentifiers":[{"nameIdentifier":"14411","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"長岡, 泰司","creatorNameLang":"ja"},{"creatorName":"ナガオカ, タイジ","creatorNameLang":"ja-Kana"}],"nameIdentifiers":[{"nameIdentifier":"14412","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"花田, 一臣","creatorNameLang":"ja"},{"creatorName":"ハナダ, カズオミ","creatorNameLang":"ja-Kana"}],"nameIdentifiers":[{"nameIdentifier":"14413","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"吉田, 晃敏","creatorNameLang":"ja"},{"creatorName":"ヨシダ, アキトシ","creatorNameLang":"ja-Kana"}],"nameIdentifiers":[{"nameIdentifier":"14414","nameIdentifierScheme":"WEKO"}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2021-07-06"}],"displaytype":"detail","filename":"5460.pdf","filesize":[{"value":"5.1 MB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"5460.pdf","url":"https://asahikawa-med.repo.nii.ac.jp/record/4654/files/5460.pdf"},"version_id":"3630cf2a-d5f9-4ca7-9ef2-11480e071efb"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"手持ち式オートレフラクトケラトメーター","subitem_subject_language":"ja","subitem_subject_scheme":"Other"},{"subitem_subject":"屈折検査","subitem_subject_language":"ja","subitem_subject_scheme":"Other"},{"subitem_subject":"集団検診","subitem_subject_language":"ja","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"眼科検診における手持ち式オートレフラクトケラトメーターの有用性","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"眼科検診における手持ち式オートレフラクトケラトメーターの有用性","subitem_title_language":"ja"}]},"item_type_id":"5","owner":"3","path":["6","7","23"],"pubdate":{"attribute_name":"PubDate","attribute_value":"2013-09-25"},"publish_date":"2013-09-25","publish_status":"0","recid":"4654","relation_version_is_last":true,"title":["眼科検診における手持ち式オートレフラクトケラトメーターの有用性"],"weko_creator_id":"3","weko_shared_id":-1},"updated":"2024-07-26T08:56:17.475420+00:00"}