{"created":"2023-06-19T11:23:27.814824+00:00","id":4005,"links":{},"metadata":{"_buckets":{"deposit":"c451244d-bf5b-43c1-bdf5-492b8196122d"},"_deposit":{"created_by":3,"id":"4005","owners":[3],"pid":{"revision_id":0,"type":"depid","value":"4005"},"status":"published"},"_oai":{"id":"oai:asahikawa-med.repo.nii.ac.jp:00004005","sets":["7","7:24"]},"author_link":["12090","12091","12092","12093","12094"],"control_number":"4005","item_5_biblio_info_21":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2012-01-01","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"1-2","bibliographicPageEnd":"181","bibliographicPageStart":"175","bibliographicVolumeNumber":"413","bibliographic_titles":[{"bibliographic_title":"Clinica Chimica Act"}]}]},"item_5_description_25":{"attribute_name":"リンクURL","attribute_value_mlt":[{"subitem_description":"【図表は本人の意向により載せません 】 | 【図表は本人の意向により載せません 】","subitem_description_type":"Other"}]},"item_5_description_33":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"Background : International external quality assessments have shown variation in results of urinary albumin among various immunoassays. A well-defined candidate reference material for urine albumin (cRM-UA) was prepared to improve standardization. Methods : cRM-UA was prepared from a commercially available preparation of human serum albumin by using gel-filtration HPLC. The value was assigned by transfer from ERM-DA470 using immunoassay systems qualified based on the linearity and variability observed in dilution tests of pooled urine and the calibrators. Effectiveness of recalibration using the cRM-UA was evaluated by measuring 129 urine specimens. Results : The cRM-UA had a monomeric albumin peak which accounted for 98.9% of the total area by gel filtration HPLC. The lyophilized preparation of the cRM-UA had suitable homogeneity, and short- and long-term stability. Nine of 14 immunoassays met the criteria were used for value assignment. The assigned concentration was 225.1 ± 9.11 mg/l [mean ± U: expanded uncertainty with k = 2] when reconstituted with 3.00 ml of purified water on weight basis. Recalibration of 7 qualified immunoassays using the cRM-UA resulted in between-method CV of 6.6%. Conclusions : The cRM-UA was successful in achieving standardization of urine albumin results among 7 immunoassays which possess performance attributes representing uniform reactivity to both cRM-UA and clinical urine samples.","subitem_description_language":"en","subitem_description_type":"Abstract"}]},"item_5_description_36":{"attribute_name":"注記","attribute_value_mlt":[{"subitem_description":"http://dx.doi.org/10.1016/j.cca.2011.09.016","subitem_description_type":"Other"}]},"item_5_description_37":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"subitem_description":"text","subitem_description_type":"Other"}]},"item_5_description_41":{"attribute_name":"フォーマット","attribute_value_mlt":[{"subitem_description":"application/pdf","subitem_description_type":"Other"}]},"item_5_relation_24":{"attribute_name":"DOI","attribute_value_mlt":[{"subitem_relation_type_id":{"subitem_relation_type_id_text":"10.1016/j.cca.2011.09.016","subitem_relation_type_select":"DOI"}}]},"item_5_source_id_22":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"0009-8981","subitem_source_identifier_type":"PISSN"}]},"item_5_text_44":{"attribute_name":"ID(XooNIps)","attribute_value_mlt":[{"subitem_text_value":"21963465"}]},"item_5_text_54":{"attribute_name":"閲覧数(XooNIps)","attribute_value_mlt":[{"subitem_text_value":"985"}]},"item_5_text_55":{"attribute_name":"ダウンロード数(XooNIps)","attribute_value_mlt":[{"subitem_text_value":"791"}]},"item_5_version_type_38":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_ab4af688f83e57aa","subitem_version_type":"AM"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"伊藤, 喜久","creatorNameLang":"ja"},{"creatorName":"イトウ, ヨシヒサ","creatorNameLang":"ja-Kana"}],"nameIdentifiers":[{"nameIdentifier":"12090","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Ichihara, Kiyoshi","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"12091","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Kish, Kouji","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"12092","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Hosogaya, Shigem","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"12093","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Yamada, Toshiyuki","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"12094","nameIdentifierScheme":"WEKO"}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2021-07-06"}],"displaytype":"detail","filename":"4464.pdf","filesize":[{"value":"378.6 kB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"4464.pdf","url":"https://asahikawa-med.repo.nii.ac.jp/record/4005/files/4464.pdf"},"version_id":"55d4bf57-00ac-4fb8-9a36-fa5e30c60528"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"Preparation of highlypurifiedmonomeric human serum albumin as secondary reference material for standardization of urinary albumin immunoassays","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Preparation of highlypurifiedmonomeric human serum albumin as secondary reference material for standardization of urinary albumin immunoassays","subitem_title_language":"en"}]},"item_type_id":"5","owner":"3","path":["6","7","24"],"pubdate":{"attribute_name":"PubDate","attribute_value":"2012-05-17"},"publish_date":"2012-05-17","publish_status":"0","recid":"4005","relation_version_is_last":true,"title":["Preparation of highlypurifiedmonomeric human serum albumin as secondary reference material for standardization of urinary albumin immunoassays"],"weko_creator_id":"3","weko_shared_id":-1},"updated":"2024-07-31T05:30:31.909950+00:00"}