{"created":"2025-02-19T23:59:09.308648+00:00","id":2000345,"links":{},"metadata":{"_buckets":{"deposit":"ee447717-22fe-4f5d-b5d8-9330960dfa1f"},"_deposit":{"created_by":3,"id":"2000345","owner":"3","owners":[3],"pid":{"revision_id":0,"type":"depid","value":"2000345"},"status":"published"},"_oai":{"id":"oai:asahikawa-med.repo.nii.ac.jp:02000345","sets":["7:27:45"]},"author_link":[],"item_10_alternative_title_3":{"attribute_name":"その他(別言語等)のタイトル","attribute_value_mlt":[{"subitem_alternative_title":"13NアンモニアPETを用いて計測した心筋血流予備能低下と心筋虚血の程度の心血管有害事象に対する相互作用の臨床研究","subitem_alternative_title_language":"ja"}]},"item_10_biblio_info_21":{"attribute_name":"bibliographic_information","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2023-10-01","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"5","bibliographicPageEnd":"2053","bibliographicPageStart":"2043","bibliographicVolumeNumber":"30","bibliographic_titles":[{"bibliographic_title":"Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology","bibliographic_titleLang":"en"}]}]},"item_10_date_granted_30":{"attribute_name":"学位授与年月日","attribute_value_mlt":[{"subitem_dategranted":"2024-06-28"}]},"item_10_degree_grantor_32":{"attribute_name":"item_10_degree_grantor_32","attribute_value_mlt":[{"subitem_degreegrantor":[{"subitem_degreegrantor_language":"ja","subitem_degreegrantor_name":"旭川医科大学"}],"subitem_degreegrantor_identifier":[{"subitem_degreegrantor_identifier_name":"10107","subitem_degreegrantor_identifier_scheme":"kakenhi"}]}]},"item_10_degree_name_31":{"attribute_name":"学位名","attribute_value_mlt":[{"subitem_degreename":"博士(医学)","subitem_degreename_language":"ja"}]},"item_10_description_28":{"attribute_name":"識別番号 その他","attribute_value_mlt":[{"subitem_description":"PMID:37012523","subitem_description_language":"en","subitem_description_type":"Other"}]},"item_10_description_33":{"attribute_name":"item_10_description_33","attribute_value_mlt":[{"subitem_description":"Background: Myocardial flow reserve (MFR) and the extent of myocardial ischemia identify patients at high risk of major adverse cardiovascular events (MACEs). Associations between positron emission tomography (PET)-assessed extent of ischemia, MFR, and MACEs is unclear.\n\nMethod: Overall, 640 consecutive patients with suspected or known coronary artery disease undergoing 13N-ammonia myocardial perfusion PET were followed-up for MACEs. Patients were categorized into three groups based on myocardial ischemia severity: Group I (n = 335), minimal (myocardial ischemia < 5%); Group II (n = 150), mild (5-10%); and Group III (n = 155), moderate-to-severe (> 10%).\n\nResults: Cardiovascular death and MACEs occurred in 17 (3%) and 93 (15%) patients, respectively. Following statistical adjustment for confounding factors, impaired MFR (global MFR < 2.0) was revealed as an independent predictor of MACEs in Groups I (hazard ratio [HR], 2.89; 95% confidence interval [CI], 1.48-5.64; P = 0.002) and II (HR, 3.40; 95% CI 1.37-8.41; P = 0.008) but was not significant in Group III (HR, 1.15; 95% CI 0.59-2.26; P = 0.67), with a significant interaction (P < 0.0001) between the extent of myocardial ischemia and MFR.\n\nConclusion: Impaired MFR was significantly associated with increased risk of MACEs in patients with ≤ 10% myocardial ischemia but not with those having > 10% ischemia, allowing a clinically effective risk stratification.","subitem_description_language":"ja","subitem_description_type":"Abstract"}]},"item_10_dissertation_number_29":{"attribute_name":"dissertation_number","attribute_value_mlt":[{"subitem_dissertationnumber":"乙第508号"}]},"item_10_relation_24":{"attribute_name":"DOI","attribute_value_mlt":[{"subitem_relation_type":"isIdenticalTo","subitem_relation_type_id":{"subitem_relation_type_id_text":"https://doi.org/10.1007/s12350-023-03255-x","subitem_relation_type_select":"DOI"}}]},"item_10_source_id_22":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"1071-3581","subitem_source_identifier_type":"PISSN"}]},"item_10_version_type_38":{"attribute_name":"出版タイプ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"open access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_abf2"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"三浦, 史郎","creatorNameLang":"ja","creatorNameType":"Personal"},{"creatorName":"ミウラ, シロウ","creatorNameLang":"ja-Kana","creatorNameType":"Personal"},{"creatorName":"Miura, Shiro","creatorNameLang":"en","creatorNameType":"Personal"}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_access","date":[{"dateType":"Available","dateValue":"2025-02-19"}],"filename":"O508 Miura Shiro_TD.pdf","filesize":[{"value":"980 KB"}],"format":"application/pdf","url":{"objectType":"fulltext","url":"https://asahikawa-med.repo.nii.ac.jp/record/2000345/files/O508 Miura Shiro_TD.pdf"},"version_id":"e793f9fb-5526-43db-8133-478c5dcb6414"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"Coronary artery disease","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"Myocardial flow reserve","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"Myocardial ischemia","subitem_subject_language":"en","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"item_resource_type","attribute_value_mlt":[{"resourcetype":"doctoral thesis","resourceuri":"http://purl.org/coar/resource_type/c_db06"}]},"item_title":"Interaction of impaired myocardial flow reserve and extent of myocardial ischemia assessed using 13N-ammonia positron emission tomography imaging on adverse cardiovascular outcomes","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Interaction of impaired myocardial flow reserve and extent of myocardial ischemia assessed using 13N-ammonia positron emission tomography imaging on adverse cardiovascular outcomes","subitem_title_language":"en"}]},"item_type_id":"10","owner":"3","path":["45"],"pubdate":{"attribute_name":"PubDate","attribute_value":"2025-02-19"},"publish_date":"2025-02-19","publish_status":"0","recid":"2000345","relation_version_is_last":true,"title":["Interaction of impaired myocardial flow reserve and extent of myocardial ischemia assessed using 13N-ammonia positron emission tomography imaging on adverse cardiovascular outcomes"],"weko_creator_id":"3","weko_shared_id":-1},"updated":"2025-02-20T00:42:36.285275+00:00"}