{"created":"2023-06-19T11:20:54.215054+00:00","id":1001,"links":{},"metadata":{"_buckets":{"deposit":"9e9b58b8-c5f5-442b-b57c-c2257376e203"},"_deposit":{"created_by":3,"id":"1001","owners":[3],"pid":{"revision_id":0,"type":"depid","value":"1001"},"status":"published"},"_oai":{"id":"oai:asahikawa-med.repo.nii.ac.jp:00001001","sets":["7","7:23"]},"author_link":["2998","2999"],"item_5_biblio_info_21":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"1997-07-01","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"57","bibliographicPageEnd":"24","bibliographicPageStart":"21","bibliographic_titles":[{"bibliographic_title":"北海道放射線技術雑誌"}]}]},"item_5_description_33":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"Stereotactic Radiosurgeryに用いられる小照射の半影測定にダイオードを利用した場合の,ダイオードの方向や構造が測定結果に与える影響を検討した.ダイオードを線錐方向に平行で,かつスキャン方向に対してビルドアップが後方になるように配置することで,より真の値が得られるものと考えられた","subitem_description_language":"ja","subitem_description_type":"Abstract"}]},"item_5_description_36":{"attribute_name":"注記","attribute_value_mlt":[{"subitem_description":"出版社版","subitem_description_type":"Other"}]},"item_5_description_37":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"subitem_description":"text","subitem_description_type":"Other"}]},"item_5_description_41":{"attribute_name":"フォーマット","attribute_value_mlt":[{"subitem_description":"application/pdf","subitem_description_type":"Other"}]},"item_5_source_id_22":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"0912-0327","subitem_source_identifier_type":"PISSN"}]},"item_5_text_44":{"attribute_name":"ID(XooNIps)","attribute_value_mlt":[{"subitem_text_value":"1998020116"}]},"item_5_text_54":{"attribute_name":"閲覧数(XooNIps)","attribute_value_mlt":[{"subitem_text_value":"1957"}]},"item_5_text_55":{"attribute_name":"ダウンロード数(XooNIps)","attribute_value_mlt":[{"subitem_text_value":"834"}]},"item_5_text_7":{"attribute_name":"著者 ローマ字","attribute_value_mlt":[{"subitem_text_value":"Nishibu, Shigemi"},{"subitem_text_language":"en","subitem_text_value":"Miyata, Takeo"},{"subitem_text_language":"en"}]},"item_5_version_type_38":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"西部, 茂美","creatorNameLang":"ja"},{"creatorName":"ニシブ, シゲミ","creatorNameLang":"ja-Kana"}],"nameIdentifiers":[{"nameIdentifier":"2998","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"宮田, 武雄","creatorNameLang":"ja"},{"creatorName":"ミヤタ, タケオ","creatorNameLang":"ja-Kana"}],"nameIdentifiers":[{"nameIdentifier":"2999","nameIdentifierScheme":"WEKO"}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2021-07-06"}],"displaytype":"detail","filename":"1202.pdf","filesize":[{"value":"1.5 MB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"1202.pdf","url":"https://asahikawa-med.repo.nii.ac.jp/record/1001/files/1202.pdf"},"version_id":"79658f56-06cd-4abd-ba5d-b764ecceb618"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"Stereotactic Radiosurgery","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"small diode dosimeter","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"diode orientation","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"dosimetic error","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"computer-aided caculation","subitem_subject_language":"en","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"Stereotactic Radiosurgeryにおける微小照射野の半影測定","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Stereotactic Radiosurgeryにおける微小照射野の半影測定","subitem_title_language":"ja"}]},"item_type_id":"5","owner":"3","path":["6","7","23"],"pubdate":{"attribute_name":"PubDate","attribute_value":"2008-09-22"},"publish_date":"2008-09-22","publish_status":"0","recid":"1001","relation_version_is_last":true,"title":["Stereotactic Radiosurgeryにおける微小照射野の半影測定"],"weko_creator_id":"3","weko_shared_id":-1},"updated":"2024-07-16T09:39:22.781165+00:00"}