{"created":"2023-06-19T11:20:54.167875+00:00","id":1000,"links":{},"metadata":{"_buckets":{"deposit":"9d39a5cd-4ff0-4597-954b-a3101ae09d8e"},"_deposit":{"created_by":3,"id":"1000","owners":[3],"pid":{"revision_id":0,"type":"depid","value":"1000"},"status":"published"},"_oai":{"id":"oai:asahikawa-med.repo.nii.ac.jp:00001000","sets":["7","7:23"]},"author_link":["2996","2997"],"item_5_biblio_info_21":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"1996-07-01","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"56","bibliographicPageEnd":"44","bibliographicPageStart":"37","bibliographic_titles":[{"bibliographic_title":"北海道放射線技術雑誌"}]}]},"item_5_description_33":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"1995年3月に当院ではVarian社製Clinac2100C及び治療計画用コンピュータCADPLANが導入された.この装置はX線エネルギーが10MVと4MVで照射可能である.今回,Radiosurgeryに用いる線量分布の容積評価をX線エネルギー別,照射方法別に行い,又,計算値と実測値の誤差の検証を行い良好な成績を得た","subitem_description_language":"ja","subitem_description_type":"Abstract"}]},"item_5_description_36":{"attribute_name":"注記","attribute_value_mlt":[{"subitem_description":"出版社版","subitem_description_type":"Other"}]},"item_5_description_37":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"subitem_description":"text","subitem_description_type":"Other"}]},"item_5_description_41":{"attribute_name":"フォーマット","attribute_value_mlt":[{"subitem_description":"application/pdf","subitem_description_type":"Other"}]},"item_5_source_id_22":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"0912-0327","subitem_source_identifier_type":"PISSN"}]},"item_5_text_44":{"attribute_name":"ID(XooNIps)","attribute_value_mlt":[{"subitem_text_value":"1997039589"}]},"item_5_text_54":{"attribute_name":"閲覧数(XooNIps)","attribute_value_mlt":[{"subitem_text_value":"2259"}]},"item_5_text_55":{"attribute_name":"ダウンロード数(XooNIps)","attribute_value_mlt":[{"subitem_text_value":"2285"}]},"item_5_text_7":{"attribute_name":"著者 ローマ字","attribute_value_mlt":[{"subitem_text_value":"Nishibu, Shigemi"},{"subitem_text_language":"en","subitem_text_value":"Hirata, Yoshiaki"},{"subitem_text_language":"en"}]},"item_5_version_type_38":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"西部, 茂美","creatorNameLang":"ja"},{"creatorName":"ニシブ, シゲミ","creatorNameLang":"ja-Kana"}],"nameIdentifiers":[{"nameIdentifier":"2996","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"平田, 良昭","creatorNameLang":"ja"},{"creatorName":"ヒラタ, ヨシアキ","creatorNameLang":"ja-Kana"}],"nameIdentifiers":[{"nameIdentifier":"2997","nameIdentifierScheme":"WEKO"}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2021-07-06"}],"displaytype":"detail","filename":"1201.pdf","filesize":[{"value":"3.2 MB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"1201.pdf","url":"https://asahikawa-med.repo.nii.ac.jp/record/1000/files/1201.pdf"},"version_id":"99264174-db6f-4fde-b71c-a20d1ca56703"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"Linear accelerator","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"Computer treatment planning system","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"Dosimetric error","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"Computer-aided calculation","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"Real dosimetric data","subitem_subject_language":"en","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"Radiosurgeryにおける線量分布の容積評価並びに計算値と実測値の検証","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Radiosurgeryにおける線量分布の容積評価並びに計算値と実測値の検証","subitem_title_language":"ja"}]},"item_type_id":"5","owner":"3","path":["6","7","23"],"pubdate":{"attribute_name":"PubDate","attribute_value":"2008-09-22"},"publish_date":"2008-09-22","publish_status":"0","recid":"1000","relation_version_is_last":true,"title":["Radiosurgeryにおける線量分布の容積評価並びに計算値と実測値の検証"],"weko_creator_id":"3","weko_shared_id":-1},"updated":"2024-07-16T09:39:22.102932+00:00"}